Phone (866) 563-6812

Note: Images may show upgrades

ArjoHuntleigh Nimbus 4 therapeutic mattress

ArjoHuntleigh Nimbus 4 combines automatic adjustment of cell pressures, Heelguard and unique vent valve technology to provide effective pressure relief and improved solutions for a wide range of resident/user management issues.

Regular Price: $7,950.90

Special Price $7,795.00



ArjoHuntleigh Nimbus 4 therapeutic mattress provides effective alternating pressure relief combined with automatic adjustment to the weight, size and position of the individual, ensuring optimum pressure relief and comfort. Nimbus 4 mattress is designed to support residents/user 550 lbs. and provides pressure redistribution for all resident/user types all stages of tissue damage. An automatt sensor pad, below the entire length of the mattress, works with the automatic pump to constantly readjust cell pressures keeping the interface pressure below 10 mmHg for up to 40% of the operating cycle.

Five heel cells incorporate vent valve technology, allows the caregiver to fully remove interface pressure from this high risk area, and providing zero pressure for the most vulnerable residents/users, such as those with limb ischaemia or existing wounds. The mattress design provides a 8” inflated cell height with an anti-sink torso section, supporting residents/users in lying or profiled positions, thereby reducing the risk of bottoming out.

Cardio Pulmonary Resuscitation (CPR) and Rapid Air Deflate Release (RADR) is a quick release, single-handed function located on the mattress control unit that enables rapid air deflation for emergencies, short-term physiotherapy, resident/user transfers and handling or storage.

Cover : Vapour permeable and water resistant 2-way stretch cover offers optimum pressure redistribution and comfort. This loose fitting top cover is attached to the mattress base by concealed zips to reduce ingress of unwanted fluids. The cover is also flame retardant, easy to clean and can be completely removed for laundering.

Heelguard : Dedicated mattress zone where bottom 5 cells provide maximum pressure relief through use of unique "power down" straps, keeping pressure at the vulnerable heel lower for longer.

Cable Management : Reduces risk of injury to user and/or carer by removing trailing cables.

Anti-sink mattress design : The mattress is made up of 20 deep "figure of 8" designed cells to support user up to 550 lbs., providing active pressure redistribution for all user types and all categories1 of tissue damage.


CPR Facility : A quick release, single handed operation, the CPR facility enables rapid air deflation for emergencies, short term physiotherapy, moving and handling or storage.

Transport Facility : Seals air in the mattressfor up to 12 hours, providing a uniform stable surface for user transportation, moving and handling nursing procedures and during periods of power failure.

Auto-Matt Sensor Pad : The Auto-Matt sensor pad ensures the user is automatically supported at optimum pressures regardless of size, height, position or weight distribution.

Wound Valve Technology : 5 heel cells incorporate Wound Valve technology, allowing the carer to permanently off-load ("float") the vulnerable heel, ideal for the most vulnerable users such as those with limb ischaemia or existing wounds.


Additional Info

Brand ArjoHuntleigh Homecare
Technical Specifications
ArjoHuntleigh Nimbus 4 mattress replacement system
Length 81"
Width 35"
Maximum height 8½"
Maximum profile height 15"
Cell height 8"
Weight 34.17 lbs.
Cover material PU coated knitted fabric
Cell material 0.011"
Max patient weight 550 lbs.
Length 20"
Height 8¾"
Depth 4"
Weight 12.5 lbs.
Case material ABS/polycarbonate blend
Supply voltage UK 220-240 VAC, 50Hz
Electrical rating 35 VA
Fuse rating F500mA
Filters All service replaceable
Operating cycle 10 minutes
Tube set
Length 39½"
Tube material 5-way moulded PVC
Tube connectors Moulded nylon
Electrical safety standards
IEC601-1 IEC 60601-1 (BS EN 60601-1) IEC 60601-1-2 (BS EN 60601-1-2) VDE 0750 Teil 1
Degree of protection against electric shock Class I, type BF
Degree of protection of ingress of liquids Ordinary
Mode of operation Continuous

Order Forms


  • ArjoHuntleigh products are warranted for a period of Twelve (12) months from the date of delivery.
  • Parts under warranty will be covered at no cost. Any labor cost for service under warranty is not covered as per our terms of sale.
  • Standard Manufacturer Terms & Conditions are applicable for Warranty of this product.
  • Click here for detailed warranty…

Please call us for specific details.


  • This is a special order item and cannot be returned.
  • All returns are subject to 25% restocking fee
  • All returns must have an RGA number (Returned Goods Authorization Number) unauthorized returns will not be accepted.
  • The products must be new, unused condition, not tampered with, in original packaging and returned at the customer's expense in the original packaging.
  • If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund
  • Hygiene products will not be returned once used or opened.
  • Custom orders are non-refundable and non-returnable.
  • Standard manufacturer Terms & Conditions are applicable for Return Policy of this product.

Please call us for specific details.

Configure size options/accessories available:

* Required Fields

Regular Price: $7,950.90

Special Price $7,795.00

Write Your Own Review

Only registered users can write reviews. Please, log in or register