A&D Medical LifeSource Basic Blood Pressure Monitor
A&D Medical LifeSource Basic Blood Pressure Monitor
Features
A&D Medical LifeSource Basic Blood Pressure Monitor With SlimFit Medium Cuff is easy to use and comes standard with just the right number of features. 15 memory recall provides ample storage for home use or while traveling. Systolic, diastolic and pulse rate are all shown simultaneously for easy review. Its irregular heart beat detection key feature alerts the user to the presence of an irregular heartbeat while still providing an accurate reading.
Features
- Battery life indicator.
- Clinically validated for accuracy.
- Cuffs are not made with natural rubber latex.
- Indicates an irregular heartbeat (IHB) during a measurement.
- Pressure Rating Indicator classifies blood pressure in accordance with medically approved standards.
User Friendly
- Displays average of all measurements.
- Stores 60 measurements in memory with recall.
- Gentle Inflation enables a more comfortable measurement.
- Easy one button operation for quick and accurate measurement.
In Box
- 1 Blood Pressure Monitor.
- 1 Blood Pressure Medium Cuff (8.6"-16.5")
- 1 Instruction Manual.
Blood Pressure Monitor Care Instructions
- Precision components are used in the construction of this device
- Extremes in temperature, humidity, direct sunlight, shock or dust should be avoided
- Clean the device and cuff with a dry, soft cloth or a cloth dampened with water and a neutral detergent
- Never use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff
- Avoid tightly folding the cuff or storing the hose tightly twisted for long periods, as such treatment may shorten the life of the components
- The device and cuff are not water resistant
- Prevent rain, sweat and water from soiling the device and cuff
- Measurements may be distorted if the device is used close to televisions, microwave ovens, cellular telephones, X-ray or other devices with strong electrical fields
- When reusing the device, confirm that the device is clean
- Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of according to the applicable local regulations
- Do not modify the device. It may cause accidents or damage to the device
- To measure blood pressure, the arm must be squeezed by the cuff hard enough to temporarily stop blood flow through the artery.
- This may cause pain, numbness or a temporary red mark to the arm. This condition will appear especially when measurement is repeated successively
- Any pain, numbness, or red marks will disappear with time
- People who have a severe circulatory deficit in the arm must consult a doctor before using the device, to avoid medical problems
- Do not self-diagnose the measurement results and start treatment by yourself
- Always consult your doctor for evaluation of the results and treatment
- Do not apply cuff on an arm with other medical equipment attached neither equipment may function properly
- Do not apply the cuff on an arm with an unhealed wound
- Do not apply the cuff on an arm receiving an intravenous drip or blood transfusion. It may cause injury or accidents
- Do not use the device where flammable gases such as anesthetic gases are present. It may cause an explosion.
- Do not use the device in highly concentrated oxygen environments, such as a highpressure oxygen chamber or an oxygen tent. It may cause a fire or explosion.
- Do not excessively bend or squeeze the air hose
Sizing
SPECIFICATIONS | |
Measurement Method | Oscillometric |
Measurement Range | Pressure: 0-299 mmHg |
Measurement Accuracy | Pressure: ±3 mmHg |
Power Supply | 4 x 1.5V batteries (R6P, LR6 or AA) |
Battery Life | Approx. 700 times LR6 (alkaline batteries) Approx. 200 times R6P (manganese batteries) |
Monitor Dimensions | 3.8 x 5.1 x 2.7” (9.6 x 13 x 6.8 cm) |
Monitor Weight | 8.5 oz (240 g) without batteries |
Display Size | 1.3 x 2.1” (3.4 x 5.3 cm) |
Clinical Test | ANSI / AAMI SP-10 1992 |
Operating Conditions | +50°F to +104°F (10°C to 40°C) / 15% to 85% RH / 800 to 1060 hPa |
Storage / Transport Conditions | -4°F to +140°F (-20°C to 60°C) / 10% to 95% RH / 700 to 1060 hPa |
Videos
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Returns
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.