  • Bard StatLock PICC Anchoring Device, Foam Anchor Pad

Bard StatLock PICC Anchoring Device, Foam Anchor Pad

SKU: BAVCDC-MI
$10.34 to $477.01

he Bard StatLock PICC Plus Catheter Stabilization Device has been shown in studies to greatly improve patient outcomes and quality of care compared to traditional forms of tape and suture PICC site stabilization. For use with peripherally inserted central catheters (PICCs), this IV Stabilizer offers great versatility and ease of use. Just lift the transparent "gull-wings" on the stabilizer, place the catheter wings over the posts, and close. STATLOCKPICC Stabilization Device is well-known for its clear, green bracket capturing the catheter wings over the posts. It is more effective and productive alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies.The STATLOCKPICC II Stabilization Device is designed for compatibility with winged PICC catheters as well as dialysis catheters, such as Medcomp Ash and Kendall MAXID Dialysis catheters.The STATLOCK PICC II Stabilization Device offers easy post stabilization ? simply press the catheter?s securement wings over posted retainer and cover with a transparent dressing.Bard StatLock PICC Plus Stabilization Device is specifically designed to stabilize PICC catheters, thereby improving patient comfort and safety while reducing potential complications associated with the traditional securement. It features a "post and door" design to house the suture wings of virtually all peripherally inserted central catheters (PICCs).Bard Medical STATLOCK PICC Anchoring Device, Foam Anchor Pad, Fixed Posts, Sterile, Latex-free

Features

  • For Adult
  • Offers great versatility
  • Improves Patient Care
  • Lowers IV Complications
  • Increases Catheter Indwell Times
  • Eliminates Accidental Needlesticks
  • Includes a device retainer and an anchor pad
  • Catheter holder with greater adhesive strength
  • Devices Help Hospitals Save Time and Money
  • Prevents needlestick risk to healthcare workers
  •  Provides solutions that follow OSHA recommendations for sutureless securement
  • Designed to reduce the potential complications associated with suture securement
  • Anchor pad available in breathable, non-absorbent tricot polyester or closed cell foam
  • Reduces catheter tip micromotion better than tape and provide greater stability over time
  • Easy to use: Lift the transparent gull-wings, place catheter wings over the posts, and close
  • Combining the latest in design and engineering technology, it releasably secures most winged catheters
  • Designed to improve patient comfort and safety by eliminating the need to secure catheters with suture
  • A more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies

Overview

  • Combining the latest in design and engineering technology, StatLock PICC Plus Stabilization Device releasably secures most winged?catheters on the market.
  • Just lift the transparents gull-wings, place catheter wings over the posts, and close.
  • Anchor pad available in breathable, nonabsorbent tricot polyester or closed cell foam.
  • StatLock PICC Plus Stabilization Device is sterile and latex-free.Just lift the transparent "gull-wings", place catheter wings over the posts and close.Anchor pad available in breathable, nonabsorbent tricot polyester or closed cell foam.
  • The StatLockPICC II Stabilization Device is designed for compatibility with winged PICC catheters as well as dialysis catheters.
  • The StatLock PICC II Stabilization Device offers easy post stabilization ? simply press the catheter?s securement wings over posted retainer and cover with a transparent dressing.
Precautions and Warning:
  • The StatLock PICC Plus stabilization device should be monitored daily and replaced if the pad is lifting, at least every 7 days.
  • The catheter insertion site should be treated per healthcare providers recommendations.
  • Alcohol and acetone may weaken the adhesive bond between the StatLock device pad and the skin. Care should be taken when using these solutions while performing catheter site care.
  • Do not use it where loss of adherence could occur, such as with a confused patient, unattended access device, diaphoretic or non-adherent skin, or when the access device is not monitored daily.
  • Observe universal blood and body fluid precautions and infection control procedures, during the application and removal.
  • Suture the StatLock stabilization device pad to skin if necessary or deemed necessary.
  • Minimize catheter manipulation during application and removal.
  • Remove oil and moisturizer from targeted skin area.
  • Orient the StatLock stabilization device so arrows point toward the catheter tip.
  • A luer-lock connector must be used to secure venous and arterial catheters.
  • Always apply the adhesive strip to central venous and arterial catheters at or near the insertion site when using a StatLock PICC Plus stabilization device.
  • This is a single-use device. Reuse/and or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patent.
  • Do not re-sterilize. The sterility of the single-use device is not guaranteed following re-sterilization because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead to infection complications. Re-sterilization may compromise the structural integrity, essential material and/or design characteristics and may lead to an unpredictable loss of functionality and/or device failure.

Direction of Usage

Technique of Application:
  • Prep:
    • Cleanse around catheter insertion and outlined stabilization site with chlorhexidine solution, alcohol or as recommended by your healthcare provider. Extend to both sides to an area larger than where the anchor pad will be placed. Allow to dry completely.
    • Apply provided skin protectant to stabilization site. Extend to both sides to an area larger than where the anchor pad will be placed. Allow to dry completely (10 to 15 seconds) until the site is smooth to the touch. Skin protectant helps to further enhance the adherence and the holding power of the anchor pad to your skin.
  • Press:
    • Align the StatLock device anchor pad so blue directional arrows point toward catheter insertion site. 
    • Sliding Posts (if the posts on the StatLock device retainer slide back and forth) - Place catheter wing hole over the first post, then slide stabilization device to capture the second post.
    • Fixed Posts (if the posts on the StatLock device retainer do not slide back and forth or do not move from side to side) - Place catheter wing holes over fixed posts.
    • Using thumbs support undersurface of anchor pad and catheter while closing retainer doors. This prevents from pushing down on the skin.
  • Peel and Place:
    • Hold the StatLock catheter anchor device securely as you peel away paper backing from anchor pad, one side at a time, then place on the skin.
    • Apply transparent dressing over catheter insertion site and/or StatLock device anchor pad as instructed by your healthcare provider.
    • Apply both provided dressing change labels.
Technique of Removal:
  • Dissolve:
    • Remove transparent dressing using "stretch technique". Apply alcohol on top of the plastic doors and edges/corners of the transparent dressing. With one edge on each side loosened, stretch in each direction by pulling the dressing horizontally across catheter to remove. Always start at the distal edge of dressing and work toward catheter to limit movement.
    • First, lift the edge of anchor pad using 3?4 alcohol pads by stacking together and squeezing alcohol onto skin and working under the edge of the pad. Then continue to stroke undersurface of the pad with alcohol to dissolve anchor pad away from the skin. Be sure to work underneath the pad and again squeeze the alcohol for easy removal. The pad should lift from the skin. Do not pull or force pad to remove.
  • Disengage:
    • Fold adhesive anchor pad underneath on both sides so it sticks to itself.
    • Stabilize catheter with a gloved finger while holding the StatLock device. Next, use the thumb of opposite hand to gently lift retainer door from behind while pressing down with the index finger as shown. Reposition hands and repeat process to open second retainer door.
    • Carefully remove PICC from the retainer.
    • Re-apply another StatLock PICC Plus stabilization device. Be sure to temporarily secure line by holding catheter with a sterile gloved finger or sterile adhesive foam strip per health care provider?s recommendations. OR
    • Discontinue line if recommended by health care provider
  • The product warranty is applicable as per the terms and conditions provided by the product manufacturer.

Please call us for specific details.

  • No returns will be accepted after 30 days from the date of shipment.
  • All returns are subject to a restocking fee as per manufacturers terms and conditions.
  • All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
  • We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
  • The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
  • If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
  • Hygiene, bath and toilet items cannot be returned once opened or used.
  • Standard manufacturer terms and conditions apply for return policy of this product.

Please call us for specific details.