The 3M Attest Biological Indicator Incubator 56°C is your trusted partner in providing the highest steam sterilization requirements in medical settings. This incubator, designed with precision and efficiency in mind, is an essential component for measuring the effectiveness of your sterilizing treatments. This 3m attest steam incubator creates an environment suitable for the growth of each test organism at the critical temperature of 56°C. The 14-vial (round) capacity enables the simultaneous incubation of numerous indications, streamlining your process and enabling thorough monitoring of sterilizing performance. Operating at 120 nominal voltage, with an acceptable range of 90–132V, the 3m biological indicator incubator is designed for dependability and versatility. Precise temperature control at 56°C is required to ensure reliable outcomes, giving healthcare workers confidence in the sterilization procedure. The user-friendly design of this biological incubator makes operating easier, allowing users to effortlessly go through the procedure. The simple interface makes it more user-friendly, while its robust build provides durability and longevity in demanding healthcare environments. The 3M Attest Biological Indicator Incubator is a beacon of excellence. It is an essential component of the medical sterilization ecosystem, ensuring that healthcare institutions adhere to the highest patient safety requirements.
Features:
Accurate Temperature Control: Ensures optimal conditions for BI activation and reliable results.
Dry Block Design: Heats consistently for uniform incubation throughout the chamber.
Easy-to-Read Indicator (possible): May have a light or display to indicate proper functioning and temperature.
Automatic Vial Crushing (possible): Some models may automatically crush the BI vial for safe and mess-free sample release.
See-Through Cover: Allows for easy observation of BI color change, indicating sterilization effectiveness.
Benefits:
Efficient Steam Sterilization Monitoring: Validates the effectiveness of steam sterilization cycles through BI growth or lack thereof.
Reliable Results: Precise temperature control ensures accurate readings and minimizes the risk of false positives or negatives.
Easy to Use: Pre-set temperature and simple design streamline the incubation process.
Safe Operation (possible): Automatic vial crushing (if available) minimizes user contact with potentially contaminated materials.
Improved Workflow: See-through cover allows for quick visual confirmation of results.
Directions:
Plug in the incubator and let it warm up for 30 minutes before use.
Keep the unit continuously on to avoid repeated warm-up periods.
After a sterilization cycle, wearing safety glasses and gloves, fully open the sterilizer door for at least 5 minutes before removing the Attest biological indicator.
If the biological indicator is not in a test pack, allow it to cool outside the sterilizer for an additional 10 minutes before crushing.
If the biological indicator is in a test pack, remove it from the sterilizer, open the pack for 5 minutes to dissipate heat, then let the indicator cool outside the pack for an extra 10 minutes before crushing.
Position the biological indicator in the incubator's metal heating block with the bottom at a 45° angle and the cap above the metal block.
Push the indicator straight back to crush the ampoule and activate it.
Push the activated indicator down to seat it in the metal heating block, ensuring the cap remains above the metal block.
Refer to the Attest biological indicator Instructions for Use for detailed directions, including result interpretation and the use of controls.
Sizing
3M Attest Biological Indicator Incubator
Manufacturer#
116
Brand
3M Attest
Application
Biological Indicator Incubator
Temperature Range
56° C EO
Latex Free Indicator
Not Made with Natural Rubber Latex
UNSPSC Code
42281526
Warranty
The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
No returns will be accepted after 30 days from the date of shipment.
All returns are subject to a restocking fee as per manufacturers terms and conditions.
All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
Hygiene, bath and toilet items cannot be returned once opened or used.
Standard manufacturer terms and conditions apply for return policy of this product.