








3M Curos Disinfecting Cap for Needleless Connector
Starts From
Description
3M Curos Disinfecting Cap is designed to disinfect and protect ports in one minute, the Curos Disinfecting Cap for Needleless Connectors contains 70% isopropyl alcohol (IPA), helping to decrease the risk of central line-associated bloodstream infection (CLABSI)1 on I.V. needleless connectors.
Protect patients’ ports and your peace of mind
Make disinfecting I.V. needleless connectors easier by placing Curos Disinfecting Cap for Needleless Connectors exactly where you need them when you need them. You can dispense them as individual caps or on a convenient five-cap strip that’s hung from an I.V. pole, ensuring easy access, greater compliance and reduced waste.
Small, yet mighty to help in the fight against BSIs
-
Convenient bedside access: Dispense Curos Disinfecting Caps as individual caps or on strips that can be hung from I.V. poles for easy access, greater compliance and reduced risk.
-
Colored bright to disinfect right: Brightly colored Curos disinfecting port protectors help you verify that I.V. access points are clean at a glance, allowing you to easily and reliably measure disinfection compliance.
Where you need them, when you need them
- Powerful one-minute disinfection: Save valuable time with fast disinfection that eliminates the need for “scrub the hub” protocols. Containing 70% isopropyl alcohol (IPA), Curos disinfecting port protectors disinfect I.V. access point surfaces in one minute. They’re proven to disinfect ports against Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Pseudomonas aeruginosa, Candida glabrata, and Candida albicans.
- Protects for up to seven days: Providing consistent I.V. access point disinfection and protection for up to seven days if not removed, Curos disinfecting port protectors eliminate human technique variance through passive disinfection.
- Protection that stays put: Meeting INS standards for add-on devices, Curos disinfecting port protectors twist on easily and luer lock securely in place on common I.V. access points including needleless connectors, male luers and open female luers such as stopcocks and catheter hubs.
You can help reduce the risk of central line-associated bloodstream infections (CLABSI)1 with Curos disinfecting caps for needleless connectors. Offering thorough disinfection and protection, these alcohol-impregnated caps easily twist onto I.V. access points and act as a physical barrier to contamination between accesses while saving you time by removing manual scrub variation and providing visual compliance confirmation.
How to use Curos disinfecting cap for needleless connectors
- Peel the foil from the Curos disinfecting cap.
- Push & twist the Curos disinfecting cap clockwise onto the end of the needleless connector.
Suggested Applications
- Disinfects needleless connectors before line access.
- Ideal for at-home use or in healthcare facilities.
- Use only on needleless connectors. Do not use on open female luers.
Clinical studies to learn how Curos disinfecting cap for needleless connectors can help reduce the rate of CLABSI1 in your facility.
- Disinfects in one minute and provides a physical barrier to contamination between accesses for up to seven days if not removed.
- Twists on easily and stays securely in place.
- Brightly colored to help clinicians verify and measure compliance.
- The effectiveness of Curos disinfecting port protectors was tested in vitro against: Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Pseudomonas aeruginosa, Candida glabrata and Candida albicans.
- Meets 2024 Infusion Therapy Standards of Practice for add-on devices published by INS.
- Single use only.
- Ensures that disinfecting supplies are readily available at the bedside to facilitate staff compliance with needleless connector disinfection.
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Resources
Description
3M Curos Disinfecting Cap is designed to disinfect and protect ports in one minute, the Curos Disinfecting Cap for Needleless Connectors contains 70% isopropyl alcohol (IPA), helping to decrease the risk of central line-associated bloodstream infection (CLABSI)1 on I.V. needleless connectors.
Protect patients’ ports and your peace of mind
Make disinfecting I.V. needleless connectors easier by placing Curos Disinfecting Cap for Needleless Connectors exactly where you need them when you need them. You can dispense them as individual caps or on a convenient five-cap strip that’s hung from an I.V. pole, ensuring easy access, greater compliance and reduced waste.
Small, yet mighty to help in the fight against BSIs
-
Convenient bedside access: Dispense Curos Disinfecting Caps as individual caps or on strips that can be hung from I.V. poles for easy access, greater compliance and reduced risk.
-
Colored bright to disinfect right: Brightly colored Curos disinfecting port protectors help you verify that I.V. access points are clean at a glance, allowing you to easily and reliably measure disinfection compliance.
Where you need them, when you need them
- Powerful one-minute disinfection: Save valuable time with fast disinfection that eliminates the need for “scrub the hub” protocols. Containing 70% isopropyl alcohol (IPA), Curos disinfecting port protectors disinfect I.V. access point surfaces in one minute. They’re proven to disinfect ports against Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Pseudomonas aeruginosa, Candida glabrata, and Candida albicans.
- Protects for up to seven days: Providing consistent I.V. access point disinfection and protection for up to seven days if not removed, Curos disinfecting port protectors eliminate human technique variance through passive disinfection.
- Protection that stays put: Meeting INS standards for add-on devices, Curos disinfecting port protectors twist on easily and luer lock securely in place on common I.V. access points including needleless connectors, male luers and open female luers such as stopcocks and catheter hubs.
You can help reduce the risk of central line-associated bloodstream infections (CLABSI)1 with Curos disinfecting caps for needleless connectors. Offering thorough disinfection and protection, these alcohol-impregnated caps easily twist onto I.V. access points and act as a physical barrier to contamination between accesses while saving you time by removing manual scrub variation and providing visual compliance confirmation.
How to use Curos disinfecting cap for needleless connectors
- Peel the foil from the Curos disinfecting cap.
- Push & twist the Curos disinfecting cap clockwise onto the end of the needleless connector.
Suggested Applications
- Disinfects needleless connectors before line access.
- Ideal for at-home use or in healthcare facilities.
- Use only on needleless connectors. Do not use on open female luers.
Clinical studies to learn how Curos disinfecting cap for needleless connectors can help reduce the rate of CLABSI1 in your facility.
- Disinfects in one minute and provides a physical barrier to contamination between accesses for up to seven days if not removed.
- Twists on easily and stays securely in place.
- Brightly colored to help clinicians verify and measure compliance.
- The effectiveness of Curos disinfecting port protectors was tested in vitro against: Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Pseudomonas aeruginosa, Candida glabrata and Candida albicans.
- Meets 2024 Infusion Therapy Standards of Practice for add-on devices published by INS.
- Single use only.
- Ensures that disinfecting supplies are readily available at the bedside to facilitate staff compliance with needleless connector disinfection.
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Resources
Starts From
