Bard StatLock PICC Plus Stabilization Device features a "post and door" design to house the suture wings of virtually all peripherally inserted central catheters (PICCs). It is specifically designed to stabilize PICC catheters, thereby improving patient comfort and safety while reducing potential complications. Combining the latest in design and engineering technology, it releasably secures most winged catheters. Bard StatLock PICC Plus Stabilization Device is specifically designed to stabilize PICC catheters, thereby improving patient comfort and safety while reducing potential complications associated with the traditional securement. It features a "post and door" design to house the suture wings of virtually all peripherally inserted central catheters (PICCs). Combining the latest in design and engineering technology, StatLock PICC Plus Stabilization Device releasably secures most winged?catheters on the market.Just lift the transparents ?gull-wings,? place catheter wings over the posts, and close. Anchor pad available in breathable, nonabsorbent tricot polyester or closed cell foam.Sterile and latex-free. StatLock Stabilization Devices are a more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies. The StatLock PICC Plus Stabilization Device is a ?post and door? design to house the suture wings of virtually all peripherally inserted central catheters (PICCs). Available in adult, pediatric and neonatal sizes.
Easy to Use
Combining the latest in design and engineering technology, StatLock PICC Plus Stabilization Device secures most winged catheters on the market with a stable but releasable adhesive.Just lift the transparent ?gull-wings,? place catheter wings over the posts and close. The anchor pad is available in breathable, nonabsorbent tricot polyester or closed cell foam. The StatLock for PICC line is sterile and latex-free. Effective and VersatileStatLock Stabilization Devices are a more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies. With a transparent dressing for easy monitoring, a latex-free adhesive for lowered allergy risk and the option of foam or tricot pads, StatLock PICC Plus provides superior PICC line stability that prevents accidental needle sticks and other catheter complications.The StatLock PICC Plus Stabilization Device is a post-and-door design that can accommodate the suture wings of virtually all peripherally inserted central catheters (PICCs) and is available in adult, pediatric and neonatal sizes.Simply prep, press, peel and place with StatLock for PICC lines.
Features
For Adult
Offers great versatility
Improves Patient Care
Lowers IV Complications
Increases Catheter Indwell Times
Eliminates Accidental Needlesticks
Includes a device retainer and an anchor pad
Catheter holder with greater adhesive strength
Devices Help Hospitals Save Time and Money
Prevents needlestick risk to healthcare workers
Provides solutions that follow OSHA recommendations for sutureless securement
Designed to reduce the potential complications associated with suture securement
Anchor pad available in breathable, non-absorbent tricot polyester or closed cell foam
Reduces catheter tip micromotion better than tape and provide greater stability over time
Easy to use: Lift the transparent gull-wings, place catheter wings over the posts, and close
Combining the latest in design and engineering technology, it releasably secures most winged catheters
Designed to improve patient comfort and safety by eliminating the need to secure catheters with suture
A more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies
Precautions and Warning:
The StatLock PICC Plus stabilization device should be monitored daily and replaced if the pad is lifting, at least every 7 days.
The catheter insertion site should be treated per healthcare providers recommendations.
Alcohol and acetone may weaken the adhesive bond between the StatLock device pad and the skin. Care should be taken when using these solutions while performing catheter site care.
Do not use it where loss of adherence could occur, such as with a confused patient, unattended access device, diaphoretic or non-adherent skin, or when the access device is not monitored daily.
Observe universal blood and body fluid precautions and infection control procedures, during the application and removal.
Suture the StatLock stabilization device pad to skin if necessary or deemed necessary.
Minimize catheter manipulation during application and removal.
Remove oil and moisturizer from targeted skin area.
Orient the StatLock stabilization device so arrows point toward the catheter tip.
A luer-lock connector must be used to secure venous and arterial catheters.
Always apply the adhesive strip to central venous and arterial catheters at or near the insertion site when using a StatLock PICC Plus stabilization device.
This is a single-use device. Reuse/and or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patent.
Do not re-sterilize. The sterility of the single-use device is not guaranteed following re-sterilization because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead to infection complications. Re-sterilization may compromise the structural integrity, essential material and/or design characteristics and may lead to an unpredictable loss of functionality and/or device failure.
Sizing
Brand
Statlock PICC Plus
Manufacturer
BD
Application
Catheter / Line Securement Device
For Use With
For Central Venous Catheters
Specifications
Pediatric, Foam Anchor Pad, Sliding Post
UNSPSC Code
42221803
Latex Free Indicator
Not Made with Natural Rubber Latex
Warranty
The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
No returns will be accepted after 30 days from the date of shipment.
All returns are subject to a restocking fee as per manufacturers terms and conditions.
All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
Hygiene, bath and toilet items cannot be returned once opened or used.
Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Detailed description
Sizing/specifications
Warranty
Return policy
Looking for more information?
Select Variant
Bard StatLock PICC Plus Stabilization Device Pediatric, Foam Anchor Pad