AG Industries Bacteria Filter for Oxygen Concentrators is a medical-grade, final-stage bacteria filter engineered for use with oxygen concentrators and respiratory equipment. This disposable filter is designed to remove airborne bacteria, viruses, and particulate debris from the oxygen air stream, providing an additional layer of protection for patients receiving oxygen therapy in home care, hospital, and clinical settings.
Primary Use and Function
This bacteria filter serves as a critical inline filtration component between the oxygen concentrator outlet and the patient's tubing connection. It removes contaminants that may compromise the quality and safety of delivered oxygen, helping to prevent respiratory infections and equipment contamination.
Key Features and Specifications
- High Filtration Efficiency: Delivers 99.999 percent bacterial filtration efficiency (BFE), effectively capturing airborne bacteria and particulate matter
- Compatible Tubing Connections: Fits both 3/16 inch stepped barb and 1/4 inch straight barb tubing connections for broad oxygen concentrator compatibility
- Quality Filter Media: Uses glass microfiber media, a proven and trusted filtration technology in respiratory equipment
- Durable Housing: Polypropylene construction provides strength and reliability
- High Flow Capacity: Supports maximum flow rates up to 100 LPM (liters per minute)
- Single-Use Design: Disposable construction ensures optimal filtration performance and eliminates cross-contamination risks
- FDA Clearance: Cleared by the FDA as a medical device (K091363) for safe use in clinical and home settings
Applications and Suitable Environments
The BF100 is appropriate for use in multiple healthcare settings including home oxygen therapy, hospitals, assisted living facilities, nursing homes, and clinical care centers. It is particularly beneficial for patients with compromised immune systems, respiratory conditions, or those at elevated risk for airborne infections.
Replacement and Maintenance Guidance
As a single-use disposable filter, the BF100 should be replaced when visibly discolored or when airflow becomes restricted. Replacement frequency varies based on individual usage patterns and environmental air quality. Most manufacturers recommend regular inspection and replacement every few weeks to months, depending on usage intensity. Always follow your oxygen concentrator's manual for specific replacement recommendations.
Installation and Compatibility Considerations
The BF100 installs easily as an inline filter between the oxygen concentrator and patient tubing. Before purchasing, verify compatibility with your specific concentrator model by checking equipment documentation. The dual barb connections (3/16 inch stepped and 1/4 inch straight) accommodate most standard oxygen tubing sizes, but confirming compatibility with your equipment is essential for safe operation.
"
Specifications
| Manufacturer | AG Industries |
| Model Number (MPN) | BF100 |
| Product Type | Final-Stage Bacteria Filter |
| Connection Types | 3/16 inch Stepped Barb and 1/4 inch Straight Barb |
| Filter Media | Glass Microfiber |
| Housing Material | Polypropylene |
| Bacterial Filtration Efficiency (BFE) | 99.999 percent |
| Maximum Flow Rate | 100 LPM (Liters Per Minute) |
| Intended Use | Oxygen concentrators and respiratory equipment |
| Unit of Measure | 1 Filter per Unit |
| Condition | New, Single-Use Disposable |
| FDA Status | FDA Cleared Medical Device (K091363) |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
FAQs
What is the AG Industries BF100 bacteria filter designed for?
The BF100 is a final-stage bacteria filter designed for oxygen concentrators and respiratory equipment. It removes airborne bacteria and particulate debris from the air stream to help ensure clean, safe oxygen delivery in home care, hospitals, and clinical settings.
What tubing connections does this filter accommodate?
The BF100 features both a 3/16 inch stepped barb and a 1/4 inch straight barb connection, making it compatible with standard tubing sizes used in many oxygen concentrator systems.
How effective is this bacteria filter at removing contaminants?
This filter offers 99.999 percent bacterial filtration efficiency (BFE), meaning it effectively removes airborne bacteria and particulate matter from the oxygen stream using glass microfiber media, a proven filtration standard in respiratory equipment.
Is the BF100 reusable or disposable?
The BF100 is a single-use, disposable filter. Once saturated with contaminants, it should be replaced with a new filter to maintain optimal filtration performance and equipment safety.
How do I know if this filter is compatible with my oxygen concentrator?
The BF100 is designed for most oxygen concentrators with 3/16 to 1/4 inch barbed tubing connections. Always verify your concentrator model's compatibility before purchase. If unsure, consult your equipment manual or contact the equipment manufacturer.
How often should I replace this filter?
Replacement frequency depends on usage and air quality in your environment. Check your oxygen concentrator's manual for specific replacement recommendations. Generally, final stage filters should be inspected regularly and replaced if visibly discolored or saturated with contaminants.
Description
AG Industries Bacteria Filter for Oxygen Concentrators is a medical-grade, final-stage bacteria filter engineered for use with oxygen concentrators and respiratory equipment. This disposable filter is designed to remove airborne bacteria, viruses, and particulate debris from the oxygen air stream, providing an additional layer of protection for patients receiving oxygen therapy in home care, hospital, and clinical settings.
Primary Use and Function
This bacteria filter serves as a critical inline filtration component between the oxygen concentrator outlet and the patient's tubing connection. It removes contaminants that may compromise the quality and safety of delivered oxygen, helping to prevent respiratory infections and equipment contamination.
Key Features and Specifications
- High Filtration Efficiency: Delivers 99.999 percent bacterial filtration efficiency (BFE), effectively capturing airborne bacteria and particulate matter
- Compatible Tubing Connections: Fits both 3/16 inch stepped barb and 1/4 inch straight barb tubing connections for broad oxygen concentrator compatibility
- Quality Filter Media: Uses glass microfiber media, a proven and trusted filtration technology in respiratory equipment
- Durable Housing: Polypropylene construction provides strength and reliability
- High Flow Capacity: Supports maximum flow rates up to 100 LPM (liters per minute)
- Single-Use Design: Disposable construction ensures optimal filtration performance and eliminates cross-contamination risks
- FDA Clearance: Cleared by the FDA as a medical device (K091363) for safe use in clinical and home settings
Applications and Suitable Environments
The BF100 is appropriate for use in multiple healthcare settings including home oxygen therapy, hospitals, assisted living facilities, nursing homes, and clinical care centers. It is particularly beneficial for patients with compromised immune systems, respiratory conditions, or those at elevated risk for airborne infections.
Replacement and Maintenance Guidance
As a single-use disposable filter, the BF100 should be replaced when visibly discolored or when airflow becomes restricted. Replacement frequency varies based on individual usage patterns and environmental air quality. Most manufacturers recommend regular inspection and replacement every few weeks to months, depending on usage intensity. Always follow your oxygen concentrator's manual for specific replacement recommendations.
Installation and Compatibility Considerations
The BF100 installs easily as an inline filter between the oxygen concentrator and patient tubing. Before purchasing, verify compatibility with your specific concentrator model by checking equipment documentation. The dual barb connections (3/16 inch stepped and 1/4 inch straight) accommodate most standard oxygen tubing sizes, but confirming compatibility with your equipment is essential for safe operation.
"
Specifications
| Manufacturer | AG Industries |
| Model Number (MPN) | BF100 |
| Product Type | Final-Stage Bacteria Filter |
| Connection Types | 3/16 inch Stepped Barb and 1/4 inch Straight Barb |
| Filter Media | Glass Microfiber |
| Housing Material | Polypropylene |
| Bacterial Filtration Efficiency (BFE) | 99.999 percent |
| Maximum Flow Rate | 100 LPM (Liters Per Minute) |
| Intended Use | Oxygen concentrators and respiratory equipment |
| Unit of Measure | 1 Filter per Unit |
| Condition | New, Single-Use Disposable |
| FDA Status | FDA Cleared Medical Device (K091363) |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
FAQs
What is the AG Industries BF100 bacteria filter designed for?
The BF100 is a final-stage bacteria filter designed for oxygen concentrators and respiratory equipment. It removes airborne bacteria and particulate debris from the air stream to help ensure clean, safe oxygen delivery in home care, hospitals, and clinical settings.
What tubing connections does this filter accommodate?
The BF100 features both a 3/16 inch stepped barb and a 1/4 inch straight barb connection, making it compatible with standard tubing sizes used in many oxygen concentrator systems.
How effective is this bacteria filter at removing contaminants?
This filter offers 99.999 percent bacterial filtration efficiency (BFE), meaning it effectively removes airborne bacteria and particulate matter from the oxygen stream using glass microfiber media, a proven filtration standard in respiratory equipment.
Is the BF100 reusable or disposable?
The BF100 is a single-use, disposable filter. Once saturated with contaminants, it should be replaced with a new filter to maintain optimal filtration performance and equipment safety.
How do I know if this filter is compatible with my oxygen concentrator?
The BF100 is designed for most oxygen concentrators with 3/16 to 1/4 inch barbed tubing connections. Always verify your concentrator model's compatibility before purchase. If unsure, consult your equipment manual or contact the equipment manufacturer.
How often should I replace this filter?
Replacement frequency depends on usage and air quality in your environment. Check your oxygen concentrator's manual for specific replacement recommendations. Generally, final stage filters should be inspected regularly and replaced if visibly discolored or saturated with contaminants.