
Corflo Controller Nasogastric Feeding Tube with Stylet, 7G Weighted Tip
5% OFF (Maximum $25)
Max discount of $25
PayPal Pay Later
Starts From
Description
Corflo Feeding Tube is designed for patients requiring intermittent or continuous enteral nutrition delivered through the nasogastric or nasoenteric route. Engineered for dependable performance, this tube provides consistent flow, supportive placement control, and suitable flexibility for patient comfort. Its durable construction and specialized weighted design assist in maintaining proper positioning, making it a suitable choice for healthcare settings seeking reliable enteral feeding solutions.
Features
- ENFit connector: No - designed for traditional enteral connector compatibility.
- Tip weight: 7g - helps support guided placement and stable positioning during feeding.
- Sterilization: Non-sterile - intended for single-patient use in controlled clinical environments.
- Bolus type: Bolus - suitable for scheduled bolus feeding routines as directed by clinical protocols.
- Tip weight type: Weighted - supports navigation through the gastrointestinal tract for effective placement.
- Tubing Length: 43 Inch - offers appropriate length for nasogastric or nasoenteric placement requirements.
Indications: AVANOS CORFLO Feeding Tube is for patients needing intermittent or continuous nasogastric/nasoenteric feeding.
Duration of Use: Validated for up to 30 days.
Tube Maintenance
- Follow hospital protocol or clinician orders.
- Flush every 4 hours with ≤20 mL water (≤10 mL in infants/children) before/after medications or when feeding stops.
- Monitor regularly; replace when clinically indicated.
Possible Complications
- Pneumothorax, GI perforation, aspiration, airway obstruction, tissue irritation/necrosis, allergic reaction, contamination, delayed diagnosis.
- Medication/nutrition delay or misdose; need for additional procedures.
MRI Safety
Weighted CORFLO tubes are MR Conditional:
- Static field ≤3 Tesla
- Spatial gradient ≤720 Gauss/cm
- Whole-body averaged SAR ≤3.0 W/kg
Warnings
- Avoid forward leaning or neck extension during insertion.
- Pre-measure length; do not over-insert (risk of kinking/occlusion).
- Coughing or resistance may indicate tracheal placement — remove the tube immediately.
- Always confirm gastric placement before use.
- Never reinsert the stylet while the tube is in the patient.
- Do not use excessive syringe force.
Note: Crush medications finely and dilute thoroughly (no visible particles) to prevent clogging.
Specifications
| Bolus Type | BOLUS |
| ENFit Connector | No |
| Primary Product Color | Yellow |
| Product Type | Feeding Tubes |
| Radiopaque | Yes |
| Requires Sterilization Prior to Use | False |
| Sterile | False |
| Tip Weight (g) | 7 |
| Tip Weight Type | Weighted |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Resources
Description
Corflo Feeding Tube is designed for patients requiring intermittent or continuous enteral nutrition delivered through the nasogastric or nasoenteric route. Engineered for dependable performance, this tube provides consistent flow, supportive placement control, and suitable flexibility for patient comfort. Its durable construction and specialized weighted design assist in maintaining proper positioning, making it a suitable choice for healthcare settings seeking reliable enteral feeding solutions.
Features
- ENFit connector: No - designed for traditional enteral connector compatibility.
- Tip weight: 7g - helps support guided placement and stable positioning during feeding.
- Sterilization: Non-sterile - intended for single-patient use in controlled clinical environments.
- Bolus type: Bolus - suitable for scheduled bolus feeding routines as directed by clinical protocols.
- Tip weight type: Weighted - supports navigation through the gastrointestinal tract for effective placement.
- Tubing Length: 43 Inch - offers appropriate length for nasogastric or nasoenteric placement requirements.
Indications: AVANOS CORFLO Feeding Tube is for patients needing intermittent or continuous nasogastric/nasoenteric feeding.
Duration of Use: Validated for up to 30 days.
Tube Maintenance
- Follow hospital protocol or clinician orders.
- Flush every 4 hours with ≤20 mL water (≤10 mL in infants/children) before/after medications or when feeding stops.
- Monitor regularly; replace when clinically indicated.
Possible Complications
- Pneumothorax, GI perforation, aspiration, airway obstruction, tissue irritation/necrosis, allergic reaction, contamination, delayed diagnosis.
- Medication/nutrition delay or misdose; need for additional procedures.
MRI Safety
Weighted CORFLO tubes are MR Conditional:
- Static field ≤3 Tesla
- Spatial gradient ≤720 Gauss/cm
- Whole-body averaged SAR ≤3.0 W/kg
Warnings
- Avoid forward leaning or neck extension during insertion.
- Pre-measure length; do not over-insert (risk of kinking/occlusion).
- Coughing or resistance may indicate tracheal placement — remove the tube immediately.
- Always confirm gastric placement before use.
- Never reinsert the stylet while the tube is in the patient.
- Do not use excessive syringe force.
Note: Crush medications finely and dilute thoroughly (no visible particles) to prevent clogging.
Specifications
| Bolus Type | BOLUS |
| ENFit Connector | No |
| Primary Product Color | Yellow |
| Product Type | Feeding Tubes |
| Radiopaque | Yes |
| Requires Sterilization Prior to Use | False |
| Sterile | False |
| Tip Weight (g) | 7 |
| Tip Weight Type | Weighted |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Resources
Starts From














