**The images on the website are for reference only and do not reflect the actual configuration of the product.** Learn more..
SKU:
CUT8K-MI
MPN:
T8K
UPC:
00815947020956

Cure Twist Ready To Use Catheter With Insertion Kit Supplies For Women

Need Help Or Advice ?Our Product Experts are here for youContact Us
Starts From
$2.36
$2.48
$0.12 OFF
Quantity
Select Variant *Select an option To Add to Cart
Gauge:
5 more
Packaging:
3 more
Save Dollars with Auto-Reorder!
Save Dollars with Auto Reorder! Get 5% OFF
Detailed description
<p>The small, attractive Cure Twist is similar to the design of a cosmetic item &ndash; so it is an ideal choice for those who value portability and discretion. It features an easy, twist-open top, polished eyelets on a straight tip, and a universal funnel end for maximum compatibility with drainage solutions. Gel lubricant provides a &lsquo;No Drip/No Mess&rsquo; cathing experience.</p> <p><b>Cure Twist Intermittent Catheter Tray Contains:</b></p> <ul> <li>Underpad</li> <li>Universal Connector</li> <li>BZK NonStain Wipe</li> <li>Ambidextrous Gloves</li> </ul> <p><b>Features</b></p> <p><b>The Cure Twist features all these benefits:</b></p> <ul> <li><b>Length:</b> 6 Inch</li> <li><b>Style:</b> Straight Tip</li> <li>Design of a cosmetic item</li> <li>No Drip/No Mess pre-lubrication</li> <li>Cure Medical supports medical research</li> <li>Female catheter, available in 8, 10, 12, 14, 16 FR</li> <li>Small, portable, and discreet with an easy, twist-off cap</li> <li>Smooth, fire-polished eyelets help enable comfortable use</li> <li>Universal funnel end for maximum compatibility with drainage solutions</li> <li>High-quality materials &ndash; not made with DEHP/DINP, BPA, or natural rubber latex offer peace of mind</li> </ul> <p><b>Self-Intermittent Catheterization Instructions for Women:</b></p> <p>Most women who perform self-intermittent catheterization sit on the toilet. (The shorter length Cure Twist is ideal for this technique because the shorter catheter is less likely to touch the toilet.) Other self-intermittent catheterization positions include sitting in a chair or wheelchair or lying down with pillows behind the back. Do what is most comfortable for you to pass the catheter into the urethra. Initially, you may want to use a mirror to help visualize the urethral opening where the catheter is inserted. It may take time for you to locate the proper opening. Eventually, most women learn to catheterize by touch and feel.</p> <ul> <li>Before you begin, gather the following materials:</li> </ul> <p>1) Cure Twist catheter in a sealed package</p> <p>2) Something to cleanse the area:&nbsp; soap, water, and a washcloth, or unscented disposable wipes &middot;</p> <p>3) A container to collect the urine if not cathing while sitting on a toilet &middot;</p> <p>4) Hand towel</p> <ul> <li>Inspect the catheter before use. If the catheter or package is damaged do not use it.</li> <li>Wash hands thoroughly with soap and water, or if not available, use an antibacterial hand cleaner.</li> <li>Lay out the equipment so it is within easy reach. Remove the easy, twist-off cap on the Cure Twist catheter package.</li> <li>Position yourself comfortably. Arrange clothing out of the way. If sitting on the toilet, spread your legs far apart. If lying down, bend your knees and place your heels together in a &ldquo;frog-like&rdquo; position (shown).</li> <li>Using the non-dominant hand, separate the labia with the thumb and forefinger to locate the urethra.</li> <li>With the labia separated, wash the urethral area from front to back thoroughly with soap, water, and washcloth or unscented disposable wipe. Never go back and forth over the urethral opening. Repeat washing from front to back with the different areas of the washcloth or throw away wipe.</li> <li>With your dominant hand, insert the Cure Twist&nbsp;gently into the urethral opening (shown). Continue to insert the catheter about 2 inches until urine begins to flow. If sitting on the toilet the urine can drain into the toilet. If lying down, place the funnel end of the catheter into a container to collect the urine. Hold it in place until urine stops flowing.</li> <li>When urine stops flowing, slowly rotate the Cure Twist&reg; catheter between your fingers while withdrawing it. If urine starts to flow again, stop withdrawing the catheter and let the urine drain. When the bladder is empty, finish removing the catheter.</li> </ul>
Sizing/specifications
<table class="table table-striped table table-bordered" style="width: 75%;"> <thead class="border_table"> </thead> <tbody> <tr class="table_bold"><!-- <th scope="row">1</th> --> <td>Brand</td> <td>Cure Twist</td> </tr> <tr class="table_bold"><!-- <th scope="row">2</th> --> <td>Manufacturer</td> <td>ConvaTec</td> </tr> <tr class="table_bold"><!-- <th scope="row">3</th> --> <td>Application</td> <td>Intermittent Catheter Tray</td> </tr> <tr class="table_bold"><!-- <th scope="row">3</th> --> <td>Collection Type</td> <td>1500 mL Collection Bag</td> </tr> <tr class="table_bold"><!-- <th scope="row">3</th> --> <td>Length</td> <td>6 Inch</td> </tr> <tr class="table_bold"><!-- <th scope="row">3</th> --> <td>Sterility</td> <td>Sterile</td> </tr> <tr class="table_bold"><!-- <th scope="row">3</th> --> <td>Style</td> <td>Female / Straight Tip</td> </tr> </tbody> </table> <style type="text/css">.table_bold{font-weight: 500;font-size: 1rem;}.table_content{font-weight: ;}.border_table{border: 1px solid black;text-align: center;} </style>
Resources
Watch Video
Warranty
<ul><li>The product warranty is applicable as per the terms and conditions provided by the product manufacturer.</li></ul><p><b>Please call us for specific details.</b></p>
Return policy
<ul><li>No returns will be accepted after 30 days from the date of shipment.</li><li>All returns are subject to a restocking fee as per manufacturers terms and conditions.</li><li>All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.</li><li>We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.</li><li><b>The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.</b></li><li>If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.</li><li>Hygiene, bath and toilet items cannot be returned once opened or used.</li><li>Standard manufacturer terms and conditions apply for return policy of this product.</li></ul><p><b>Please call us for specific details.</b>

Looking for more information?

Select Variant
Cure Twist Ready to Use Catheter with insertion kit supplies for Women
$2.36$2.48
Select Gauge :
  • 8 Fr

  • 10 Fr

  • 12 Fr

  • 14 Fr

  • 16 Fr

  • Select Packaging :
  • Each

  • Box

  • Case

  • Select Group