ExelInt International Hypodermic Needles - Regular Bevel
Product Information
ExelInt International Hypodermic Needles, Regular Bevel Images
**The images on the website are for reference only and do not reflect the actual configuration of the product.** Learn more..
ExelInt International Hypodermic Needles, Regular Bevel
Product Configuration Options
Starts From
Quantity
Product Features and Policies

FSA/HSA Eligible
Product Features and Policies

FSA/HSA Eligible
Airtite provides superior quality at an affordable price. Made of regular wall surgical stainless steel with polypropylene hub. They are available in a wide range of gauge and length combinations. FDA registered, CE Mark, ISO certified. The hypodermic needle is a single-use, sharp bevel-edged, hollow tubular device intended to be inserted beneath the skin of a patient while connected to a non-invasive device to administer and/or withdraw (aspirate) fluids/drugs; it may also be used for fluid/drug preparation.
Intended Use
The hypodermic needle is used in conjunction with syringes, and infusion/transfusion sets to inject fluids into, or withdraw fluids from, the body.
Indications for Use/Target Users
- Hypodermic needles are equipped with a male Luer/Luer lock connector that can be used in conjunction with syringes and infusion/transfusion sets.
- The device is designed for use by a qualified physician or clinician.
- Hypodermic needles are indicated for use with the general patient population.
Benefits of Use
- Safe, easy to use.
- Sharp, stainless-steel needle.
- Rapid delivery of fluids.
- Prevent cross-contamination between patients.
- Each needle is individually packaged, sterilized, and ready for use.
Warnings/Precautions
- Handle with care to avoid needle sticks.
- Do not replace original needle cover after use.
- Use once and discard immediately in accordance with local safety standards.
- If needle is bent or damaged, no attempt should be made to straighten needle or use the product.
- Do not bend or apply extra force on the needle tube as it may lead to needle tube breakage when the bending angle exceeds 25° for regular-walled needle tube and 20° for thin wall.
- For single use only.
- Do not reuse. Reuse of needle can result in contamination or transmit disease.
- Do not reprocess
Contraindications
- There are no recognized contraindications for the use of hypodermic needles.
Sterility
- Hypodermic Needles are sterilized by EO gas sterilization (indicated by ) single use only.
- Do not re-use .
- Do not re-sterilize.
- Inspect each package prior to use.
- Do not use the component if any seal or cavity is damaged or breached or if the expiration date has been exceeded. Once opened the device must be used or discarded.
Operating Instructions
- Separate at upper package edge and peel apart to point below the hub.
- Affix and tighten the syringe or female luer to the needle using aseptic technique. Grip the base of the needle and turn the syringe or luer clockwise.
- Fill the syringe with fluid according to established technique.
- Remove the needle cap and perform the procedure according to established technique.
- After the procedure, discard of the needle in a biohazard container according to local safety standards.
Storage
- Store at room temperature 15°C-25°C. 9.2 Do not store in high temperatures and humidity.
- Keep away from direct sunlight.
- Store in a cool and dry place.
Model No: | Gauge | Length (in) | Hub Color |
26400 | 27G | 1/2” | Medium Grey |
26401 | 26G | 3/8" | Brown |
26402 | 26G | 1/2" | Brown |
26403 | 25G | 5/8" | Orange |
26405 | 25G | 1" | Orange |
26406 | 25G | 1-1/2" | Orange |
26407 | 23G | 3/4" | Deep Blue |
26408 | 23G | 1" | Deep Blue |
26409 | 23G | 1-1/2” | Deep Blue |
26410 | 22G | 3/4" | Black |
26411 | 22G | 1" | Black |
26412 | 22G | 1-1/2” | Black |
26413 | 22G | 1-1/4" | Black |
26414 | 21G | 1" | Deep Green |
26415 | 21G | 1-1/4" | Deep Green |
26416 | 21G | 1-1/2” | Deep Green |
26417 | 20G | 1" | Yellow |
26418 | 20G | 1-1/2” | Yellow |
26419 | 18G | 1" | Pink |
26420 | 18G | 1-1/2” | Pink |
26421 | 16G | 1" | Purple |
26423 | 16G | 3/4" | Purple |
26424 | 19G | 1" | Cream |
26425 | 25G | 3/4" | Orange |
26426 | 27G | 1-1/2” | Medium Grey |
26427 | 27G | 1-1/4" | Medium Grey |
26430 | 20G | 3/4" | Yellow |
26431 | 20G | 1/2" | Yellow |
26436 | 22G | 1/2" | Black |
26437 | 30G | 1/2" | Yellow |
26438 | 19G | 1-1/2” | Cream |
26439 | 30G | 1" | Yellow |
26448* | 28G | 3/4" | Blue-Green |
26460 | 20G | 2" | Yellow |
Sizing
Brand | ExelInt |
Manufacturer | AirTite Products |
Application | Hypodermic Needle |
Bevel Type | Beveled Point |
Hub Connecting Type | Standard Luer Connection |
Hub Material | Polypropylene Hub |
Needle Material | Stainless Steel Needle |
Safety Feature | Without Safety |
Sterility | Sterile |
Style | Straight Style |
Type | General Use |
Usage | Disposable |
Wall Type | Regular Wall |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Airtite provides superior quality at an affordable price. Made of regular wall surgical stainless steel with polypropylene hub. They are available in a wide range of gauge and length combinations. FDA registered, CE Mark, ISO certified. The hypodermic needle is a single-use, sharp bevel-edged, hollow tubular device intended to be inserted beneath the skin of a patient while connected to a non-invasive device to administer and/or withdraw (aspirate) fluids/drugs; it may also be used for fluid/drug preparation.
Intended Use
The hypodermic needle is used in conjunction with syringes, and infusion/transfusion sets to inject fluids into, or withdraw fluids from, the body.
Indications for Use/Target Users
- Hypodermic needles are equipped with a male Luer/Luer lock connector that can be used in conjunction with syringes and infusion/transfusion sets.
- The device is designed for use by a qualified physician or clinician.
- Hypodermic needles are indicated for use with the general patient population.
Benefits of Use
- Safe, easy to use.
- Sharp, stainless-steel needle.
- Rapid delivery of fluids.
- Prevent cross-contamination between patients.
- Each needle is individually packaged, sterilized, and ready for use.
Warnings/Precautions
- Handle with care to avoid needle sticks.
- Do not replace original needle cover after use.
- Use once and discard immediately in accordance with local safety standards.
- If needle is bent or damaged, no attempt should be made to straighten needle or use the product.
- Do not bend or apply extra force on the needle tube as it may lead to needle tube breakage when the bending angle exceeds 25° for regular-walled needle tube and 20° for thin wall.
- For single use only.
- Do not reuse. Reuse of needle can result in contamination or transmit disease.
- Do not reprocess
Contraindications
- There are no recognized contraindications for the use of hypodermic needles.
Sterility
- Hypodermic Needles are sterilized by EO gas sterilization (indicated by ) single use only.
- Do not re-use .
- Do not re-sterilize.
- Inspect each package prior to use.
- Do not use the component if any seal or cavity is damaged or breached or if the expiration date has been exceeded. Once opened the device must be used or discarded.
Operating Instructions
- Separate at upper package edge and peel apart to point below the hub.
- Affix and tighten the syringe or female luer to the needle using aseptic technique. Grip the base of the needle and turn the syringe or luer clockwise.
- Fill the syringe with fluid according to established technique.
- Remove the needle cap and perform the procedure according to established technique.
- After the procedure, discard of the needle in a biohazard container according to local safety standards.
Storage
- Store at room temperature 15°C-25°C. 9.2 Do not store in high temperatures and humidity.
- Keep away from direct sunlight.
- Store in a cool and dry place.
Model No: | Gauge | Length (in) | Hub Color |
26400 | 27G | 1/2” | Medium Grey |
26401 | 26G | 3/8" | Brown |
26402 | 26G | 1/2" | Brown |
26403 | 25G | 5/8" | Orange |
26405 | 25G | 1" | Orange |
26406 | 25G | 1-1/2" | Orange |
26407 | 23G | 3/4" | Deep Blue |
26408 | 23G | 1" | Deep Blue |
26409 | 23G | 1-1/2” | Deep Blue |
26410 | 22G | 3/4" | Black |
26411 | 22G | 1" | Black |
26412 | 22G | 1-1/2” | Black |
26413 | 22G | 1-1/4" | Black |
26414 | 21G | 1" | Deep Green |
26415 | 21G | 1-1/4" | Deep Green |
26416 | 21G | 1-1/2” | Deep Green |
26417 | 20G | 1" | Yellow |
26418 | 20G | 1-1/2” | Yellow |
26419 | 18G | 1" | Pink |
26420 | 18G | 1-1/2” | Pink |
26421 | 16G | 1" | Purple |
26423 | 16G | 3/4" | Purple |
26424 | 19G | 1" | Cream |
26425 | 25G | 3/4" | Orange |
26426 | 27G | 1-1/2” | Medium Grey |
26427 | 27G | 1-1/4" | Medium Grey |
26430 | 20G | 3/4" | Yellow |
26431 | 20G | 1/2" | Yellow |
26436 | 22G | 1/2" | Black |
26437 | 30G | 1/2" | Yellow |
26438 | 19G | 1-1/2” | Cream |
26439 | 30G | 1" | Yellow |
26448* | 28G | 3/4" | Blue-Green |
26460 | 20G | 2" | Yellow |
Brand | ExelInt |
Manufacturer | AirTite Products |
Application | Hypodermic Needle |
Bevel Type | Beveled Point |
Hub Connecting Type | Standard Luer Connection |
Hub Material | Polypropylene Hub |
Needle Material | Stainless Steel Needle |
Safety Feature | Without Safety |
Sterility | Sterile |
Style | Straight Style |
Type | General Use |
Usage | Disposable |
Wall Type | Regular Wall |
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.