Airtite provides superior quality at an affordable price. Made of regular wall surgical stainless steel with polypropylene hub. They are available in a wide range of gauge and length combinations. FDA registered, CE Mark, ISO certified. The hypodermic needle is a single-use, sharp bevel-edged, hollow tubular device intended to be inserted beneath the skin of a patient while connected to a non-invasive device to administer and/or withdraw (aspirate) fluids/drugs; it may also be used for fluid/drug preparation.
Intended Use
The hypodermic needle is used in conjunction with syringes, and infusion/transfusion sets to inject fluids into, or withdraw fluids from, the body.
Indications for Use/Target Users
Hypodermic needles are equipped with a male Luer/Luer lock connector that can be used in conjunction with syringes and infusion/transfusion sets.
The device is designed for use by a qualified physician or clinician.
Hypodermic needles are indicated for use with the general patient population.
Benefits of Use
Safe, easy to use.
Sharp, stainless-steel needle.
Rapid delivery of fluids.
Prevent cross-contamination between patients.
Each needle is individually packaged, sterilized, and ready for use.
Warnings/Precautions
Handle with care to avoid needle sticks.
Do not replace original needle cover after use.
Use once and discard immediately in accordance with local safety standards.
If needle is bent or damaged, no attempt should be made to straighten needle or use the product.
Do not bend or apply extra force on the needle tube as it may lead to needle tube breakage when the bending angle exceeds 25° for regular-walled needle tube and 20° for thin wall.
For single use only.
Do not reuse. Reuse of needle can result in contamination or transmit disease.
Do not reprocess
Contraindications
There are no recognized contraindications for the use of hypodermic needles.
Sterility
Hypodermic Needles are sterilized by EO gas sterilization (indicated by ) single use only.
Do not re-use .
Do not re-sterilize.
Inspect each package prior to use.
Do not use the component if any seal or cavity is damaged or breached or if the expiration date has been exceeded. Once opened the device must be used or discarded.
Operating Instructions
Separate at upper package edge and peel apart to point below the hub.
Affix and tighten the syringe or female luer to the needle using aseptic technique. Grip the base of the needle and turn the syringe or luer clockwise.
Fill the syringe with fluid according to established technique.
Remove the needle cap and perform the procedure according to established technique.
After the procedure, discard of the needle in a biohazard container according to local safety standards.
Storage
Store at room temperature 15°C-25°C. 9.2 Do not store in high temperatures and humidity.
Keep away from direct sunlight.
Store in a cool and dry place.
Model No:
Gauge
Length (in)
Hub Color
26400
27G
1/2”
Medium Grey
26401
26G
3/8"
Brown
26402
26G
1/2"
Brown
26403
25G
5/8"
Orange
26405
25G
1"
Orange
26406
25G
1-1/2"
Orange
26407
23G
3/4"
Deep Blue
26408
23G
1"
Deep Blue
26409
23G
1-1/2”
Deep Blue
26410
22G
3/4"
Black
26411
22G
1"
Black
26412
22G
1-1/2”
Black
26413
22G
1-1/4"
Black
26414
21G
1"
Deep Green
26415
21G
1-1/4"
Deep Green
26416
21G
1-1/2”
Deep Green
26417
20G
1"
Yellow
26418
20G
1-1/2”
Yellow
26419
18G
1"
Pink
26420
18G
1-1/2”
Pink
26421
16G
1"
Purple
26423
16G
3/4"
Purple
26424
19G
1"
Cream
26425
25G
3/4"
Orange
26426
27G
1-1/2”
Medium Grey
26427
27G
1-1/4"
Medium Grey
26430
20G
3/4"
Yellow
26431
20G
1/2"
Yellow
26436
22G
1/2"
Black
26437
30G
1/2"
Yellow
26438
19G
1-1/2”
Cream
26439
30G
1"
Yellow
26448*
28G
3/4"
Blue-Green
26460
20G
2"
Yellow
Sizing
Brand
ExelInt
Manufacturer
AirTite Products
Application
Hypodermic Needle
Bevel Type
Beveled Point
Hub Connecting Type
Standard Luer Connection
Hub Material
Polypropylene Hub
Needle Material
Stainless Steel Needle
Safety Feature
Without Safety
Sterility
Sterile
Style
Straight Style
Type
General Use
Usage
Disposable
Wall Type
Regular Wall
Warranty
The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
No returns will be accepted after 30 days from the date of shipment.
All returns are subject to a restocking fee as per manufacturers terms and conditions.
All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
Hygiene, bath and toilet items cannot be returned once opened or used.
Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Detailed description
Sizing/specifications
Warranty
Return policy
Looking for more information?
Select Variant
ExelInt International Hypodermic Needles, Regular Bevel