MIC Gastro-Enteral (GE) Feeding Tube Kits
5% OFF (Maximum $25)
Max discount of $25
PayPal Pay Later
Starts From
Description
MIC Gastro-Enteric Feeding Tube Kit is designed to enable simultaneous jejunal feeding and gastric decompression, supporting patients who require advanced enteral nutrition management. This specialized tube features multiple feeding exit holes to promote optimal flow and help reduce the risk of clogging. It includes clearly marked gastric and jejunal ports for easy identification and accurate medication or formula delivery. Inserted surgically through the abdominal wall, the tube delivers nutrition directly into the small intestine while also allowing the removal of excess gas or secretions from the stomach. Your healthcare provider will select the appropriate tube and provide detailed care instructions to ensure safe use and long-term tube performance.
Features
- FDA approved and CE marked.
- Silicone internal retention balloon.
- Medical-grade silicone construction.
- Multiple gastric and jejunal exit ports.
- Jejunal feeding port and gastric decompression port for dual-function support.
- Fully opaque jejunal tubing with tungsten-weighted tip for placement control.
- SECUR-LOK external retention ring promotes air circulation around the stoma and helps prevent tube migration.
MIC Gastro-Enteric Feeding Tube Kit Includes:
- (1) Gastroenteric Tube
- (1) Directions for Use
- (1) Guidewire (0.025 inch) for 16 Fr., 18 Fr. Tubes
- (1) Guidewire (0.035inch) for 20 Fr., 22 Fr., 24 Fr., 26 Fr., 28 Fr., 30 Fr. Tubes
Balloon Capacity:
- 25.4 cm Jejunal Length: 3-5ml Balloon.
- 57.9 cm Jejunal Length: 7-10ml Balloon.
Indications
Used for enteral feeding and gastric decompression in gastroparesis, motility disorders, head injury/stroke, or when feeding distal to the stomach is needed.
Daily Care
Keep the stoma and tube clean & dry daily. Supplies: soap/water, 4×4s or tissues, syringe, cotton swabs, diet soft drink (for declogging). Lift the SECUR-LOK ring, gently clean the skin, rinse, and dry completely. Check the stoma/tube at every feeding.
Contraindications
- Ascites, Peritonitis, Portal hypertension, Colonic interposition, Uncorrected coagulopathy, Uncertain tract length/abdominal wall thickness
Possible Complications
- Aspiration, Tube clog/leakage/dislodgement, Infection, abscess, skin breakdown, Buried bumper syndrome, Pressure necrosis, Perforation, bleeding, hypergranulation
DO’S
- DO use a feeding pump
- DO keep all ports & exterior tube clean
- DO flush tube 3–5× daily
- DO use only liquid medications
- DO adjust SECUR-LOK ring 1–2 mm from skin
- DO wash your hands before touching the tube/stoma
- DO report pain, fever, bleeding, or swelling immediately
DON’TS
- DON’T clamp the tube
- DON’T fill the balloon with air
- DON’T use blenderized diets or crushed meds
- DON’T use oil-based creams/petroleum jelly
- DON’T push the SECUR-LOK ring against the skin
- DON’T tape over the ring or healthy skin
- DON’T use unprescribed formulas
Warning
- Never remove or replace the MIC Gastro-Enteric Tube yourself — only a clinician may do this.
- If the skin around the tube is red, sore, or irritated, contact your physician immediately.
- Patients on elemental feeds via the jejunal port must use a feeding pump for accurate delivery and to keep the tube open.
- Single-use device — do not reuse, reprocess, or resterilize. Doing so can damage the tube, cause infection, or lead to serious injury/illness/death.
Caution
- Follow your doctor’s orders for gastric care.
- If on continuous feeding, flush the tube at least 3–5 times daily.
- Never puncture any part of the tube.
Note:
- Verify package integrity. Do not use if the package is damaged or the sterile barrier compromised.
- The risk for perforation may be higher in patients weighing <10kg.
| Model No | Diameter (Fr) | Jejunal Length (cm) | Silicone Internal Retention Balloon Volume (ml) |
| 0210-16 | 16 | 57.9 | 7-10 |
| 0210-16LV | 16 | 25.4 | 3-5 |
| 0210-18 | 18 | 57.9 | 7-10 |
| 0210-18LV | 18 | 25.4 | 3-5 |
| 0210-20 | 20 | 57.9 | 7-10 |
| 0210-22 | 22 | 57.9 | 7-10 |
| 0210-24 | 24 | 57.9 | 7-10 |
| 0210-26 | 26 | 57.9 | 7-10 |
| 0210-28 | 28 | 57.9 | 7-10 |
| 0210-30 | 30 | 57.9 | 7-10 |
Specifications
| Manufacturer | Avanos Medical |
| Application | Low Profile Gastrostomy Tube Kit |
| Material | Silicone |
| Sterility | Sterile |
| ENFit Connector | No |
| Feed Set Connector Type | Catheter Tip |
| Jejunal Feeding Port | Yes |
| Medication Port | No |
| Radiopaque Stripe | No |
| Sterilization Method | Gamma |
| Tube Tip Type | Tungsten Weighted Tip |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Description
MIC Gastro-Enteric Feeding Tube Kit is designed to enable simultaneous jejunal feeding and gastric decompression, supporting patients who require advanced enteral nutrition management. This specialized tube features multiple feeding exit holes to promote optimal flow and help reduce the risk of clogging. It includes clearly marked gastric and jejunal ports for easy identification and accurate medication or formula delivery. Inserted surgically through the abdominal wall, the tube delivers nutrition directly into the small intestine while also allowing the removal of excess gas or secretions from the stomach. Your healthcare provider will select the appropriate tube and provide detailed care instructions to ensure safe use and long-term tube performance.
Features
- FDA approved and CE marked.
- Silicone internal retention balloon.
- Medical-grade silicone construction.
- Multiple gastric and jejunal exit ports.
- Jejunal feeding port and gastric decompression port for dual-function support.
- Fully opaque jejunal tubing with tungsten-weighted tip for placement control.
- SECUR-LOK external retention ring promotes air circulation around the stoma and helps prevent tube migration.
MIC Gastro-Enteric Feeding Tube Kit Includes:
- (1) Gastroenteric Tube
- (1) Directions for Use
- (1) Guidewire (0.025 inch) for 16 Fr., 18 Fr. Tubes
- (1) Guidewire (0.035inch) for 20 Fr., 22 Fr., 24 Fr., 26 Fr., 28 Fr., 30 Fr. Tubes
Balloon Capacity:
- 25.4 cm Jejunal Length: 3-5ml Balloon.
- 57.9 cm Jejunal Length: 7-10ml Balloon.
Indications
Used for enteral feeding and gastric decompression in gastroparesis, motility disorders, head injury/stroke, or when feeding distal to the stomach is needed.
Daily Care
Keep the stoma and tube clean & dry daily. Supplies: soap/water, 4×4s or tissues, syringe, cotton swabs, diet soft drink (for declogging). Lift the SECUR-LOK ring, gently clean the skin, rinse, and dry completely. Check the stoma/tube at every feeding.
Contraindications
- Ascites, Peritonitis, Portal hypertension, Colonic interposition, Uncorrected coagulopathy, Uncertain tract length/abdominal wall thickness
Possible Complications
- Aspiration, Tube clog/leakage/dislodgement, Infection, abscess, skin breakdown, Buried bumper syndrome, Pressure necrosis, Perforation, bleeding, hypergranulation
DO’S
- DO use a feeding pump
- DO keep all ports & exterior tube clean
- DO flush tube 3–5× daily
- DO use only liquid medications
- DO adjust SECUR-LOK ring 1–2 mm from skin
- DO wash your hands before touching the tube/stoma
- DO report pain, fever, bleeding, or swelling immediately
DON’TS
- DON’T clamp the tube
- DON’T fill the balloon with air
- DON’T use blenderized diets or crushed meds
- DON’T use oil-based creams/petroleum jelly
- DON’T push the SECUR-LOK ring against the skin
- DON’T tape over the ring or healthy skin
- DON’T use unprescribed formulas
Warning
- Never remove or replace the MIC Gastro-Enteric Tube yourself — only a clinician may do this.
- If the skin around the tube is red, sore, or irritated, contact your physician immediately.
- Patients on elemental feeds via the jejunal port must use a feeding pump for accurate delivery and to keep the tube open.
- Single-use device — do not reuse, reprocess, or resterilize. Doing so can damage the tube, cause infection, or lead to serious injury/illness/death.
Caution
- Follow your doctor’s orders for gastric care.
- If on continuous feeding, flush the tube at least 3–5 times daily.
- Never puncture any part of the tube.
Note:
- Verify package integrity. Do not use if the package is damaged or the sterile barrier compromised.
- The risk for perforation may be higher in patients weighing <10kg.
| Model No | Diameter (Fr) | Jejunal Length (cm) | Silicone Internal Retention Balloon Volume (ml) |
| 0210-16 | 16 | 57.9 | 7-10 |
| 0210-16LV | 16 | 25.4 | 3-5 |
| 0210-18 | 18 | 57.9 | 7-10 |
| 0210-18LV | 18 | 25.4 | 3-5 |
| 0210-20 | 20 | 57.9 | 7-10 |
| 0210-22 | 22 | 57.9 | 7-10 |
| 0210-24 | 24 | 57.9 | 7-10 |
| 0210-26 | 26 | 57.9 | 7-10 |
| 0210-28 | 28 | 57.9 | 7-10 |
| 0210-30 | 30 | 57.9 | 7-10 |
Specifications
| Manufacturer | Avanos Medical |
| Application | Low Profile Gastrostomy Tube Kit |
| Material | Silicone |
| Sterility | Sterile |
| ENFit Connector | No |
| Feed Set Connector Type | Catheter Tip |
| Jejunal Feeding Port | Yes |
| Medication Port | No |
| Radiopaque Stripe | No |
| Sterilization Method | Gamma |
| Tube Tip Type | Tungsten Weighted Tip |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Starts From