Avanos MIC Silicone Jejunal Feeding Tube

Product Information

SKU:
AV0200-12LV-MI
MPN:
0200-12LV

MIC Silicone Jejunal Feeding Tube

Paypal Pay later
Pay low as $9.3/month with Pay Pal's pay later service

Starts From

Current Price: $203.01
Original Price: $213.16
Savings: $10.15 OFF

Quantity

Select product quantity
Select Variant *Select an option To Add to Cart
Balloon Capacity:
2 more
Gauge:
7 more

MIC Silicone Jejunal Feeding Tube Purchase Options

Auto Reorder Information

Save Dollars with Auto-Reorder!
Save Dollars with Auto Reorder! Get 5% OFF

Product Features and Policies

Description

The MIC Silicone Jejunal Feeding Tube has been introduced into your stomach via the abdominal wall. It provides nourishment just beyond the stomach, in the small intestine. This tube allows your body to take in the food and fluids it requires. Your doctor has chosen the appropriate tube for you and has given you instructions for its care and maintenance. You have also been given instructions for your meals and medicines, which will be provided via tube. Follow the directions exactly and never use another diet or medicine.

MIC Bolus Gastrostomy Feeding Tube is utilized for patients who are on a bolus feeding regimen. It has medical-grade silicone construction for visibility and drapability, and an inflatable silicone internal retention balloon. Features a Secur-Lok external retention ring, which is designed to allow air to circulate the stoma site and reduce tube pressure 360 degrees from the sides of the stoma wall.

Features

  • Medication port.
  • Gamma Sterilized.
  • Radiopaque stripe.
  • Universal feeding port connector.
  • FDA approved and CE marked.
  • Secur-Lok external retention ring.
  • Medical-grade silicone construction.
  • Inflatable silicone internal retention balloon.
  • Trimmable distal tip - from the distal end to the balloon tip.

Care and Use

The MIC Jejunal Feeding Tube must be cared for daily. Care is simple, consisting mainly of keeping the tube and skin around the tube (stoma) clean and dry.

Keep the following supplies on hand to make your cleaning task easier:

  • Soap and water
  • Cotton-tip swabs
  • Tissue
  • Diet soft drink for use as a cleaning solution
  • A disposable syringe
  • Clean hands

Maintenance of the MIC Jejunal Feeding Tube

Inspect the skin around the tube (the stoma) and the tube routinely before feedings to make sure they are clean. Lift the edges of the SECUR-LOK* Ring and gently clean the skin around the tube (stoma) using cotton-tip swabs or a soft cloth and warm, soapy water.

If the skin around the tube appears red or irritated, consult your physician at once. Always wash your hands with warm, soapy water before touching your tube.

Care and Use

Inspect and clean the tube.

Clean and dry the outside of the tube and both sides of the SECUR-LOK Ring using cotton-tip swabs. The SECUR-LOK Ring can be cleaned in place, or you can slide the ring up the tube for cleaning.

If the skin around the tube (stoma) appears red or irritated, consult your physician at once. Flush the tube.

After every use, flush the tube with 20 ml to 30 ml of water for adults and 10 ml to 15 ml for children or infants. The tube should be clear of medicine or feeding solutions. Wipe down the feeding port and its closure using a swab or soft cloth to remove any build-up of oils or feeding materials. If the patient is on continuous feeding, the tube should be flushed at least three times daily.

Avoid puncturing any part of the MIC*Jejunal Feeding Tube. A patient or caretaker should not attempt to change this tube.

Problem Solving

Problem Cause Remedy
Gastric leakage The SECUR-LOK Ring is not properly adjusted or the balloon is not against the stomach wall. The balloon is underinflated. Check the SECUR-LOK Ring adjustment: 1 mm to 2 mm (thickness of a dime) away from the opening. If the SECUR-LOK Ring is properly adjusted, add water in small increments (1 ml to 2 ml) to the balloon. Water can be added as the stomach size and balloon volume will allow: 20 ml FOR STANDARD VOLUME BALLOON INFLATION, 5 ml FOR LOW VOLUME BALLOON INFLATION. Make sure that the skin around the tube (stoma) is clean and dry. Wait 15 minutes and check to see if the problem has been corrected. If the problem has not been corrected, notify your physician.
Feeding tube disconnects Build-up of oily deposits. Keep the feeding port and the feeding bag connector clean. Remove oily build-up with a diet soft drink. Use a tiny amount of this solution on a cotton-tip swab, and clean the top two inches of the inside of the tube.
SECUR-LOK Ring slips Build-up of skin oils or other lubricants on the tube. Clean the tube. Wash the tube with warm, soapy water. If oil remains, clean the tube with a small amount of diet soft drink. After cleaning, re-adjust the SECUR-LOK Ring, 1 mm to 2 mm (about the thickness of a dime) away from the skin, and make sure the balloon is up against the stomach wall. DO NOT APPLY EXCESSIVE TENSION. Check in one hour to be sure that the SECUR-LOK Ring is still holding the tube properly in place. If the problem has not been corrected, notify your physician.
Tube decreasing in length Oily build-up on the tube is resulting in the SECUR-LOK Ring not holding. Clean the tube and the SECUR-LOK Ring following the instructions in #3 above.
The tube is increasing in length. Balloon under-inflated or inoperative. Withdraw water from the balloon and compare the volume against the amount originally used to fill the balloon. If the balloon is under-inflated, fill it again to the original volume. Recheck the volume periodically. If size continues to change, notify your physician. The tube may need to be replaced. Notify your physician.
Balloon leak or rupture Variable. Notify your physician.
Patient vomits and/ or aspirates stomach contents Jejunal tube may have dislodged. The formula rate may be set too high. Notify your physician.
The formula will not flow freely through the jejunal tube Jejunal tube could be clogged. Irrigate with 20–30 ml of water (adults), or 10–15 ml (children). If resistance is felt or water does not flow freely, call a physician immediately.

DO’S

  • DO report unusual symptoms such as abdominal pain, abdominal discomfort, abdominal tenderness, abdominal distension, unexplained fever, or an unusual amount of bleeding through or around the tube to your health care practitioner.
  • DO wash your hands before handling the tube or your stoma.
  • DO flush your tube with each use—no less than 3–5 times a day.
  • DO keep the feeding port clean.
  • DO keep the exterior of the tube clean.
  • DO adjust the SECUR-LOK Ring properly.
  • DO use commercially prepared liquid medications.

DON’TS

  • DON’T secure the tube in place with tape.
  • DON’T let feeding solutions stand in the tube.
  • DON’T use any diet not prescribed by the physician.
  • DON’T cover the SECUR-LOK Ring or healthy skin with tape or gauze.
  • DON’T fill the balloon with air.
  • DON’T push the SECUR-LOK Ring onto the abdomen.
  • DON’T put pressure on the opening (stoma).
  • DON’T clamp the tube.
  • DON’T use oil-based lubricants or petroleum jelly on the tube.
  • DON’T use crushed medication.

Details

Sizing/specifications
Brand MIC
Manufacturer Avanos Medical
Application Jejunal Feeding Tube
Material Silicone
Sterility Sterile
ENFit Connector No
Feed Set Connector Type Catheter Tip
Jejunal Feeding Port Yes
Medication Port No
Radiopaque Stripe Yes
Sterilization Method Gamma
Tube Tip Type Trimmable Distal Tip

Details

Warranty
  • The product warranty is applicable as per the terms and conditions provided by the product manufacturer.

Please call us for specific details.

Details

Return policy
  • No returns will be accepted after 30 days from the date of shipment.
  • All returns are subject to a restocking fee as per manufacturers terms and conditions.
  • All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
  • We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
  • The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
  • If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
  • Hygiene, bath and toilet items cannot be returned once opened or used.
  • Standard manufacturer terms and conditions apply for return policy of this product.

Please call us for specific details.

Looking for more information?

Opens a form to submit your question to the community

Unanswered Questions

    Questions and Answers

    Customer Reviews

    Select Variant

    MIC Silicone Jejunal Feeding Tube

    Price information$203.01$213.16
    Product Options

    Product Configuration Options

    Select Balloon Capacity option

    Select Balloon Capacity :

    Select Gauge option

    Select Gauge :

    Select Group

    Group Product Options

    Additional Content

    Product Details