
MiniLoc Safety Infusion Set without Y-injection Site
Starts From
Description
MiniLoc Safety Infusion Set's low profile and small footprint design make it the optimal needle for dressing the access site. The small size of the needle and the downward angle of the tubing coming off of the back of the device help to maintain dressing integrity.
Features
- Low profile
- Light weight
- Site visibility
- Dual lumen port compatible
- Priming Volume (mL): 0.3
- Small footprint ideal for dressing
- Available sizes: 19, 20, and 22 Gauge x 0.5" (12.7 mm), 0.75" (19 mm), 1" (25 mm) and 1.5" (38 mm).
Benefits
- Downward angled tubing to help maintain dressing integrity.
- Dual lumen port adaptable to enable simultaneous infusions.
- Low profile and small footprint enable the site to be easily dressed.
- Audible, tactile and visual click to confirm engaged safety mechanism.
- Safety feature covers needlepoint to help reduce risk of injury and exposure to bloodborne pathogens.
Safety Mechanism: As the needle is removed from the port and enters the base of the needle an orange safety shield rotates over the needle point and locks the needle into place. A tactile feel, audible click and visual confirmation verify the engaged safety mechanism for safe removal, transporting and disposal of the MiniLoc needle.
All BD Port Access Needles
- Are non-coring to help minimize septum damage
- Offer optional "Y" injection site for secondary access
- Are available in a variety of lengths and gauge sizes
| Model No: | Needle Length (mm) | Needle Length (in) | Needle Gauge Size | Minimum Gravity Flow Rate (mL/hr) |
| 0632015 | 38 | 1.5” | 20 | 960 |
| 0632215 | 38 | 1.5” | 22 | 312 |
| 0632034 | 19 | 0.75" | 20 | 960 |
| 0632210 | 25 | 1.0” | 22 | 312 |
| 0632250 | 12.7 | 0.5" | 22 | 312 |
| 0632234 | 19 | 0.75” | 22 | 312 |
| 0632250 | 12.7 | 0.5" | 22 | 312 |
| 0631910 | 25 | 1.0” | 19 | 1680 |
Specifications
| Manufacturer | BD |
| Brand | MiniLoc |
| Y-Site | No |
| NFC | No |
| Siliconized | Yes |
| Power Injectable | No |
| DEHP | DEHP-Free |
| Latex | Latex-Free |
| Sterilization | Ethylene Oxide |
| Shelf Life | 3 Years |
| Classification | IIa |
| Application | Huber Infusion Set |
| Hub Type | Winged Hub |
| Needle Material | Stainless Steel |
| Port Type | Without Port |
| Priming Volume | 0.3 mL Priming Volume |
| Safety Feature | Sliding Safety Needle |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Description
MiniLoc Safety Infusion Set's low profile and small footprint design make it the optimal needle for dressing the access site. The small size of the needle and the downward angle of the tubing coming off of the back of the device help to maintain dressing integrity.
Features
- Low profile
- Light weight
- Site visibility
- Dual lumen port compatible
- Priming Volume (mL): 0.3
- Small footprint ideal for dressing
- Available sizes: 19, 20, and 22 Gauge x 0.5" (12.7 mm), 0.75" (19 mm), 1" (25 mm) and 1.5" (38 mm).
Benefits
- Downward angled tubing to help maintain dressing integrity.
- Dual lumen port adaptable to enable simultaneous infusions.
- Low profile and small footprint enable the site to be easily dressed.
- Audible, tactile and visual click to confirm engaged safety mechanism.
- Safety feature covers needlepoint to help reduce risk of injury and exposure to bloodborne pathogens.
Safety Mechanism: As the needle is removed from the port and enters the base of the needle an orange safety shield rotates over the needle point and locks the needle into place. A tactile feel, audible click and visual confirmation verify the engaged safety mechanism for safe removal, transporting and disposal of the MiniLoc needle.
All BD Port Access Needles
- Are non-coring to help minimize septum damage
- Offer optional "Y" injection site for secondary access
- Are available in a variety of lengths and gauge sizes
| Model No: | Needle Length (mm) | Needle Length (in) | Needle Gauge Size | Minimum Gravity Flow Rate (mL/hr) |
| 0632015 | 38 | 1.5” | 20 | 960 |
| 0632215 | 38 | 1.5” | 22 | 312 |
| 0632034 | 19 | 0.75" | 20 | 960 |
| 0632210 | 25 | 1.0” | 22 | 312 |
| 0632250 | 12.7 | 0.5" | 22 | 312 |
| 0632234 | 19 | 0.75” | 22 | 312 |
| 0632250 | 12.7 | 0.5" | 22 | 312 |
| 0631910 | 25 | 1.0” | 19 | 1680 |
Specifications
| Manufacturer | BD |
| Brand | MiniLoc |
| Y-Site | No |
| NFC | No |
| Siliconized | Yes |
| Power Injectable | No |
| DEHP | DEHP-Free |
| Latex | Latex-Free |
| Sterilization | Ethylene Oxide |
| Shelf Life | 3 Years |
| Classification | IIa |
| Application | Huber Infusion Set |
| Hub Type | Winged Hub |
| Needle Material | Stainless Steel |
| Port Type | Without Port |
| Priming Volume | 0.3 mL Priming Volume |
| Safety Feature | Sliding Safety Needle |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Starts From














