NeoMed Polyurethane Nasogastric Feeding Tube, Non Enfit

SKU:NEFTS5-0P-EO-MI
MPN:FTS5.0P-EO

Starts From

$16.46
$17.28Save $0.82
Subscribe & Save
Save 5%
$15.64$16.46
Secure transaction
Your payment information is processed securely.
Sterile Product
Sterile Product
Latex Free
Latex Free

Description

NeoMed Enteral Feeding Tube is designed with open distal tips that are smooth and free from sharp edges or concealed cavities, helping support atraumatic insertion and removal. Unlike large cut side holes that may allow tissue migration into the ports—potentially contributing to distal tip damage or tissue disruption upon withdrawal—this design promotes safer enteral access. Engineered for nasogastric and/or orogastric feeding, the tube supports reliable nutrition delivery while emphasizing patient safety and clinical performance.

Features

  • BPA-free construction.
  • DEHP-free materials.
  • Latex-free design to support material safety.
  • Soft medical-grade polymers help support nutritive sucking, developmental care, and improved clinical outcomes.
  • Designed to help reduce risks associated with contaminated feeding tubes that may compromise gastrointestinal health.
  • Semi-encapsulated radiopaque stripe with bold insertion markings up to at least 32 cm to assist with placement verification.
  • Cost-effective solution validated for indwell time up to 30 days, helping minimize additional tube placements.
  • Plugged-style hub closure design supports reduced bacterial growth compared to hubs without lumen-sealing capability or with hidden reservoirs, threads, caps, or ridges.

Intended User: This device is intended for use by healthcare professionals.

Patient Target Group: This device is intended for patients of all age groups who require nasogastric or orogastric enteral feeding.

Indications for Use: This product is indicated for neonatal and pediatric patients to provide nutrition via nasal or oral gastric placement and is not intended for use beyond 30 days.

Contraindications: The NEOMED Feeding Tube is not intended for individual use longer than 30 days or for patients with congenital anomalies of the gastrointestinal tract above the stomach requiring surgical intervention. Follow hospital feeding tube replacement and maintenance procedures or current Academy of Nutrition and Dietetics (AND) recommendations, as applicable.

Recommended Placement Procedure:

Insertion Measurement: measure from the tip of the nose to the earlobe and then from the earlobe to midway between the xyphoid process and the umbilicus. Centimeter markings are provided on the catheter to assist in the feeding tube placement

A strip of sterile tape can be placed at the target insertion depth of the feeding tube for reference.

Insert the tube slowly and cautiously into the mouth or nose (lubricant is optional); allow the infant to swallow as the tube is advanced.

Continue to advance to the predetermined length.

Precautions: avoid inadvertent placement of the tube into the trachea or inadequate insertion such that the proximal side hole is not fully placed in the stomach. Secure the feeding tube either by holding the tube or taping it to the patient before checking for placement.

Verify Feeding Tube Placement: Finalize securement, and verify and document according to hospital protocol (e.g., chest radiograph, aspiration of gastric contents / pH testing). If the tip placement remains uncertain, reposition or remove

Recommended Maintenance

The feeding tube should be visually checked for correct position before each administration utilizing tube markings position before each administration utilizing tube markings. Verify proper tube placement before each administration according to hospital protocol.

Routinely inspect the patient’s nostrils and mouth for tolerating the feeding tube position.

Flush the feeding tube with sterile water before and after each administration.

Plug feeding tube with tethered closure when not in use.

Recommended Feeding Tube Removal

Flush the feeding tube with 0.5cc–1cc of sterile water.

Plug with a tethered closure and/or clamp the feeding tube during tube removal to minimize the risk of aspirating fluids into the trachea during withdrawal.

Gently and slowly withdraw the feeding tube and discard per standard hospital protocol and/or local or national regulations.

Document the feeding tube removal.

Clinical Benefits: Nasogastric/ Oralgastric Feeding Tubes shall facilitate nutrition (and fluid and medication) delivery to the stomach via the nose or mouth.

Device Lifetime: Device has been validated for use for up to 30 days.

Specifications

Brand NeoMed
Manufacturer Avanos Medical
Application Nasogastric Feeding Tube
Material Polyurethane
Sterility Sterile
Tethered Cap Yes
Sterilization Method Ethylene Oxide
Radiopaque Stripe Yes
Primary Product Color Orange / Purple

Warranty

  • The product warranty is applicable as per the terms and conditions provided by the product manufacturer.

Please call us for specific details.

Return

  • No returns will be accepted after 30 days from the date of shipment.
  • All returns are subject to a restocking fee as per manufacturers terms and conditions.
  • All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
  • We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
  • The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
  • If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
  • Hygiene, bath and toilet items cannot be returned once opened or used.
  • Standard manufacturer terms and conditions apply for return policy of this product.

Please call us for specific details.