Sealed Gel Battery by MK Battery has special re-sealing vent system and capable of up to 1100 cycles. The sealed battery is sealed with gel/suspended electrolyte, has less than 2% per month self-discharge and has deep cycle ability for heavy demand applications. No equalization charging required and allows faster recharge. The sealed gel battery has longer life and minimal dry out over extended use. The battery ensures consistent and reliable performance for long-term dependability.
SKU
Description
MKM24-SGB-S
Group 24 Sealed Gel Battery by MK Battery
It eliminates corrosive acid fumes and spills
The battery is maintenance free and has no need of adding water periodically
Capable of up to 1100 cycles for a typical HME user and allows faster recharge
Sealed valve regulated battery with a gel/suspended electrolyte and is designed for health and medical equipment
Features Individual Plate Formation (IPF) technology which optimizes power capacity, cell consistency and long-term reliability
MKM24-SGB-FT-S
Group 24 FT Sealed Gel Battery by MK Battery
The battery has no liquid of any kind and is completely sealed
Maintenance free and has no need of adding water periodically, it eliminates corrosive acid fumes and spills
Allows faster recharge and is capable of up to 1100 cycles for a typical home and medical equipment user
Special re-sealing vent system, which prevents excessive internal pressure, thus it cannot explode under normal conditions
MKE27-SGB-S
Group 27 Sealed Gel Battery by MK Battery
Maintenance free and has no need of adding water periodically, it eliminates corrosive acid fumes and spills
Sealed valve regulated battery with gel/suspended electrolyte and is designed for health and medical equipment
Allows for faster recharge and is capable of up to 1100 cycles for typical home and medical equipment user
Designed with individual plate formation (IPF) technology to optimize power capacity, cell consistency and long-term reliability
The gelled electrolyte battery has a special re-sealing vent system which prevents excessive internal pressure, thus it cannot explode under normal conditions
MKE31-SGB-S
Group 31 Sealed Gel Battery by MK Battery
Valve regulated gel/suspended electrolyte battery designed for health and medical equipment
Maintenance free and eliminates periodic watering, corrosive acid fumes and spills
Allows faster recharge and is capable of up to 1100 cycles for a typical HME user
Features quality construction that ensures consistent and reliable performance for long-term dependability
MKM34-SGB-S
Group 34 Sealed Gel Battery by MK Battery
Gelled/suspended electrolyte that has no liquid of any kind, completely sealed and is safe in any position
The individual plate formation (IPF) technology optimizes power capacity, cell consistency and long-term reliability
Gelled electrolyte battery has a special re-sealing vent system, which prevents excessive internal pressure, thus it cannot explode under normal conditions
M24 SLD G M24 SLD G-P M24 SLD G FT M24 SLD G FT-P E27 SLD G E27 SLD G-P E31 SLD G E31 SLD G-P M34 SLD G M34 SLD G-P
Sizing
Sealed Gel Battery by MK Battery
Model
Group 24 Battery
Group 24FT Battery
Group 27 Battery
Group 31 Battery
Group 34 Battery
Length
10.20"
10.20"
12.83"
12.93"
10.20"
Width
6.56"
6.80"
6.56"
6.74"
6.64"
Height
9.24"
8.24"
9.33"
9.75"
7.05"
Nominal voltage
12 Volts.
12 Volts.
12 Volts.
12 Volts.
12 Volts.
Capacity at C/100
84.5 Ah
84.5 Ah
99 Ah
108 Ah
70 Ah
Capacity at C/20
73.6 Ah
73.6 Ah
88 Ah
97.6 Ah
60 Ah
Capacity at C/5
63 Ah
63 Ah
72 Ah
80.5 Ah
47.5 Ah
Plate alloy
Lead calcium
Lead calcium
Lead calcium
Lead calcium
Lead calcium
Posts
Forged terminals & bushings
Forged terminals & bushings
Forged terminals & bushings
Forged terminals & bushings
Forged terminals & bushings
Container/cover
Polypropylene
Polypropylene
Polypropylene
Polypropylene
Polypropylene
Operating temperature range
-76°F - 140°F
76°F - 140°F
76°F - 140°F
76°F - 140°F
76°F - 140°F
Charge voltage @ 77°F
13.8 - 14.6 volts, cycle
13.8 - 14.6 Volts, cycle
13.8 - 14.6 Volts, cycle
13.8 - 14.6 Volts, cycle
13.8 - 14.6 Volts, cycle
13.4 - 13.6 volts, float
13.4 - 13.6 volts, float
13.4 - 13.6 volts, float
13.4 - 13.6 volts, float
13.4 - 13.6 volts, float
Vent
Self-sealing
Self-sealing
Self-sealing
Self-sealing
Self-sealing
Electrolyte
Sulfuric acid thixotropic gel
Sulfuric acid thixotropic gel
Sulfuric acid thixotropic gel
Sulfuric acid thixotropic gel
Sulfuric acid thixotropic gel
Terminal
G (T881)
C (Insert with ¼" - 20" round hole)
B (T876)
B (T876)
C (Insert with ¼" - 20" round hole)
Weight
-
51.5 lbs.
-
-
38.5 lbs.
Warranty
The manufacturer will replace the battery with a free equivalent if it fails due to defects in materials or workmanship within 13 months from the date of the initial installation.
A battery used in a mobility application rated lower than 20 amp hours will be replaced with a free equivalent if it fails due to defects in materials or workmanship within 6 months from the date of installation.
Proof of date of purchase/installation required for all claims.
Upon receipt of the defective battery, manufacturer will process the claim and reimburse for any direct freight costs.
Warranty does not cover failures in service due to the following conditions:
Normal "wear and tear".
Unauthorized modifications or alterations to the products.
Negligence, accident, abuse, misuses including improper jump starting, or improper, unsuitable or abnormal storage of the products.
Improperly installed or applied batteries. Improperly charged (either under or over) batteries. Opening of batteries that are designed and intended in use as sealed products.
Physical damage due to acts of nature or man which stress products beyond design limits or other undesirable influences.
Manufacturer considers AGM batteries to be suitable for light duty mobility equipment only. AGM batteries used in more robust applications such as complex rehab mobility devices, where daily deep discharges are the norm, may void the warranty.
Any storage of batteries shall be at an ambient temperature of 77°F or less and user shall give a freshening charge to all batteries every 6 months.
Manufacturer shall not be liable for consequential, incidental, special or direct damages, whether the claim for any such damages is based on warranty, tort, contract, or otherwise.
Any labor cost for service under warranty is not covered as per our terms of sale.
Standard manufacturer terms & conditions are applicable for warranty for this product.
Please call us for specific details.
Return
Products return policy is applicable as per the standard manufacturer terms & conditions provided.