Portex Thermovent T2 Heat and Moisture Exchanger provides effective humidification for individuals who breathe normally but have their upper airways bypassed by a tracheostomy tube. Smiths Medical Portex® Thermovent® T2 11mL dead space is a sterile, single use heat and moisture exchanger. Thermovent T2 device has a centrally situated integrated oxygen line connection connector that allows for supplemental oxygen without interfering with the other operations. Thermovent T2 HME is a passive humidifier made specifically for tracheostomy tubes.
Features:
Smooth, rounded edges aids patient comfort
Device can be used for a maximum period of 24 hours
Clear housing gives an aesthetic appearance and allows visualisation ofcontamination
Simple opening port allows quick and easy access for a suction catheter to aid the removal of secretions
Integrated oxygen port that can provide up to 60% oxygen concentrations to the patient via the simplest of connections
Sizing
Portex Thermovent T2 Heat and Moisture Exchanger
Moisture output
25mg 1-1 H2O @15 breath/min-1 Tidal volume 500ml
Resistance to flow
0.3 hPa (cmH2O) at gas flow rate 0.5l/sec-1 (30l/min) [0.6cm H2O 1-1 sec-1]
0.7 hPa (cmH2O) at gas flow rate 1.0l/sec-1 (60l/min) [0.7cm H2O 1-1 sec-1]
1.2 hPa (cmH2O) at gas flow rate 1.5l/sec-1 (90l/min) [0.9cm H2O 1-1 sec-1]
Dead space
11 ml
Inspired Oxygen Concentration (%)
15 breath/min
Tidal volume
500 ml
O2 l/min
1 2 3 4 5 6 7 8 9 10
O2%
27 33 37 42 45 47 53 54 57 60
Warranty
The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
No returns will be accepted after 30 days from the date of shipment.
All returns are subject to a restocking fee as per manufacturers terms and conditions.
All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
Hygiene, bath and toilet items cannot be returned once opened or used.
Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Questions and Answer
Ask a Question
Hover Here To Zoom IN
**The images used on the website are for reference only and does not reflects the actual configuration of the product. Learn more..