NeoMed GravityPro Gravity Feeding Syringe is intended for oral and enteral administration. These offset syringes can be used to deliver lipids first in a horizontally positioned syringe pump. All syringes include a hands-free tip cap to promote the aseptic technique.
Features
Promotes Aseptic Technique.
Allows air flushing with the same syringe.
Designed with an integrated hanger for user convenience.
Incorporates a vent zone that allows the plunger to stay in place.
Indications for Use
The device is indicated for use as a dispenser, a measuring device and an oral fluid transfer device. It is used to inject fluids into the body via extension sets and feeding tubes in neonatal and pediatric patients.
Contraindications
The GRAVITYPRO Oral Syringe is intended for one-time use. Each syringe should be used for one dispensing and one patient.
Warnings
Do not autoclave or re-use syringe as this may increase risk of leakage or biological infection.
Tip caps are a choking hazard. Keep out of reach of children.
Precautions
Always attach the syringe to a NEOMED* Feeding Tube or extension set prior to moving the plunger gasket into the vent zone, as fluid will flow immediately when the plunger gasket is positioned in the vent zone.
Do not invert the syringe when the plunger gasket is within the vent zone.
Feeding Preparation
Follow physician’s instructions or hospital protocol in opening package and use of contents. Use aseptic technique.
Identify the vent zone on the syringe (See Fig.1 and Fig. 2.2).
Fully depress the plunger before filling the syringe. Draw liquid (e.g. formula or mother’s milk) into syringe. For accurate measurement, use the black leading edge of the gasket toward the plunger tip. The accuracy of measurements is ±4% of expelled volume. Do not fill or attempt delivery past the maximum graduation. Do not position plunger gasket in the vent zone during preparation.
To expel excess air bubbles, ensure the plunger is not positioned in the vent zone. Hold syringe with tip pointing up and tap side of syringe to cause bubbles to rise toward tip. Draw back slightly on plunger taking care to not draw back into the vent zone. Push plunger upward to eject air in barrel and tip. Repeat until bubbles are eliminated
Place the tip cap on the syringe and label as per hospital protocol (label not included).
Gravity Feeding
Feeding should be administered via enteral-only connectors. This syringe is not designed for use with Luer connections. To minimize potential for clogging, mix any supplements or additives thoroughly to achieve uniform consistency.
Invert the syringe and remove tip cap. Draw back on the plunger until the plunger gasket is just above the vent zone
Attach syringe to a NEOMED Feeding Tube or Extension Set.
Using the integrated hanger, hang the syringe. For maximum volume delivery, ensure the off-center tip is oriented to the opposite side of the integrated hanger (See Fig. 2.1 and 2.3).
Holding the syringe barrel, gently pull back on the plunger until the plunger gasket is positioned within the vent zone. Fluid will immediately begin to flow (See Fig. 2.2).
Plunger gasket may remain in the vent zone for the duration of the feed.
After feeding, dispose of the syringe per hospital protocol and local or national regulations
Manual and Pump Feeding
Follow physician’s instructions or hospital protocol for proper manual and pump feeding.
Always ensure the plunger gasket is not in the vent zone when manual or pump feeding
Sizing
Manufacturer
Avanos Medical
Product Brand
NeoMed GravityPro
Primary Device Identifier (GTIN)
00350770002651
ENFit Connector
No
Kit, Pack or Tray
False
Single Use
True
Volume (ml)
100
Sterile
Yes
Application
Gravity Feeding Syringe
Graduation Color
Orange Markings
Material
Polypropylene
Packaging Type
Blister Pack
Plunger Color
Translucent Plunger
Safety Feature
Without Safety
Tip Type
Oral Tip
Style
Flat Top Style
UNSPSC Code
42142610
Warranty
The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
No returns will be accepted after 30 days from the date of shipment.
All returns are subject to a restocking fee as per manufacturers terms and conditions.
All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
Hygiene, bath and toilet items cannot be returned once opened or used.
Standard manufacturer terms and conditions apply for return policy of this product.