**The images on the website are for reference only and do not reflect the actual configuration of the product.** Learn more..
SKU:
QU20122-MI
Brand:
Quidel
MPN:
20122

QuickVue+ Strep A Test Kit

Paypal Pay later
Pay low as $4.49/month with Pay Pal's pay later service
Need Help Or Advice ?Our Product Experts are here for youContact Us
Starts From
$97.97
$102.87
$4.90 OFF
Quantity
Select Variant *Select an option To Add to Cart
Packaging:
2 more
Save Dollars with Auto-Reorder!
Save Dollars with Auto Reorder! Get 5% OFF
Latex Free

Latex Free

FSA/HSA Eligible

FSA/HSA Eligible

Detailed description
<p>The QuickVue+ Strep A Test is designed for the rapid detection of Group A Streptococcal antigen directly from throat swabs and beta-hemolytic colonies recovered from culture. Intended for use by healthcare professionals, this test aids in diagnosing Group A Streptococcal infection.</p> <p>Group A Streptococcus is a primary cause of pharyngitis. Early diagnosis and treatment of Group A Streptococcal pharyngitis can reduce the severity of symptoms and prevent serious complications such as rheumatic fever and glomerulonephritis. Traditional culture methods require 24-48 hours for results.</p> <p>The QuickVue+ Strep A Test is a lateral-flow immunoassay using a highly specific and sensitive antibody to Group A Strep antigen. To perform the test, a throat swab specimen is collected and antigen is extracted with Reagents A and B. The extracted sample is then added to the Test Cassette. If the sample contains Strep A antigen, a pink vertical line (|) appears in the Read Result Window, forming a plus sign (+) with the pre-printed blue horizontal line (&ndash;) to indicate a positive result. If Strep A is not present, only the pre-printed blue horizontal line (&ndash;) will appear, indicating a negative result. The Control Window will turn pink, confirming that the detection antibody is active and the test is functioning correctly.</p> <p><b>Features:</b></p> <ul> <li>Two-color, +/- result for easy interpretation.</li> <li>Results in only 5 minutes, allowing for test and treatment in the same office visit.</li> <li>Two reagents simplify the process with fewer steps and minimal training required.</li> </ul> <p><b>Contents Included:</b></p> <ul> <li>(25) Test Cassettes</li> <li>(1) Extraction Reagant A</li> <li>(1) Extraction Reagant B</li> <li>(25) Sterile Throat Swabs</li> <li>(25) Tubes and Tips</li> <li>(1) Postive Control</li> <li>(1) Negative Control</li> <li>(1) Package Insert</li> <li>(1) Procedure Card</li> </ul> <p><b>Warnings and Precautions:</b></p> <ul> <li>For in vitro diagnostic use.</li> <li>Do not use kit contents after the expiration date printed on the outside of the kit.</li> <li>Use appropriate precautions in the collection, storage, handling, and disposal of patient samples and used kit contents.</li> <li>Use of Nitrile or Latex gloves is recommended when handling patient samples.</li> <li>Dispose of containers and unused contents in accordance with Federal, State, and Local requirements.</li> <li>DO NOT interchange caps among reagents.</li> <li>The Test Cassette must remain sealed in the foil pouch until just prior to use.</li> <li>Reagent A contains 27.6% sodium nitrite and may be harmful if ingested or absorbed.</li> <li>Reagent B contains an acidic solution. If the solution contacts the skin or eye, flush with large volumes of water.</li> <li>Do not use Reagent B if solution is green prior to mixing with Reagent A in the Tube. If this occurs, contact Quidel Technical Support.</li> <li>To obtain accurate results, you must follow the Package Insert instructions.</li> </ul> <p><b>Storage:</b> Store kit at room temperature, 59&ndash;86&deg;F (15&ndash;30&deg;C). Kit contents are stable until the expiration date printed on the outer box. Do not freeze.</p> <h2 class="pro-feat-heading">Test Procedure:</h2> <div class="row pro-feat-align-center"> <div class="col-sm-2"><img src="https://cdn.medicaleshop.com/b8529a76-0595-4dd8-90db-86e8185ec1d1_strep-a-test-1.jpg" /></div> <div class="col-sm-10"> <p><b>Step 1:</b></p> <ul> <li>Remove the test Cassette from the foil pouch and place it on a level surface.</li> <li>Put a clean Tube in the Tube Well of the Test Cassette. Squeeze 4 DROPS of Reagent A and 4 DROPS of Reagent B into the Tube. The solution should turn green once Reagent B is added.</li> <li>Note: when adding drops, hold bottle vertically so that a complete drop forms.</li> </ul> </div> </div> <div class="row pro-feat-align-center"> <div class="col-sm-2"><img src="https://cdn.medicaleshop.com/0d7bebe0-8e75-409a-9156-e2a98675f26d_strep-a-test-2.jpg" /></div> <div class="col-sm-10"> <p><b>Step 2:</b></p> <ul> <li>Immediately place the Throat Swab into the Tube. Mix solution thoroughly by swirling the swab 5 times (or vortex briefly).</li> <li>Wait 1 minute.</li> </ul> </div> </div> <div class="row pro-feat-align-center"> <div class="col-sm-2"><img src="https://cdn.medicaleshop.com/6c7fc177-12f2-40dd-b9cf-7d8a645d0c59_strep-a-test-3.jpg" /></div> <div class="col-sm-10"> <p><b>Step 3:</b></p> <ul> <li>Remove the Tube from the Tube Well. Express all liquid from the Swab head by rolling the Swab against the inside of the Tube and squeezing firmly as it is withdrawn from the Tube. Discard the Swab.</li> <li>Put a clean Tip on the Tube.</li> </ul> </div> </div> <div class="row pro-feat-align-center"> <div class="col-sm-2"><img src="https://cdn.medicaleshop.com/38ac98b2-8809-4433-b861-fb3b02d26b4f_strep-a-test-4.jpg" /></div> <div class="col-sm-10"> <p><b>Step 4:</b></p> <ul> <li>Add 2 DROPS from the Tube to the round Sample Well in the test Cassette</li> </ul> </div> </div> <div class="row pro-feat-align-center"> <div class="col-sm-2"><img src="https://cdn.medicaleshop.com/fbe24de7-e10d-4d1e-b07b-d9fadaaf24c0_strep-a-test-5.jpg" /></div> <div class="col-sm-10"> <p><b>Step 5:</b></p> <ul> <li>For a valid result the test must be read in 10 minutes or less after adding the sample and there must be ANY shade of blue in the Test Complete Window.</li> <li>If there is no shade of blue in the Test Complete Window at 10 minutes, the result is invalid.</li> </ul> </div> </div> <style type="text/css">.pro-feat-extra-heading { background-color: #f6f6f6; font-weight: 600; text-align: center; padding: 8px; line-height: 26px; letter-spacing: 0.4px; margin-bottom: 20px; } .pro-feat-heading { background-color: #666666; font-weight: 600; color: #fff; text-align: center; padding: 8px; line-height: 26px; letter-spacing: 0.4px; margin-bottom: 20px; } .pro-feat-text-center { text-align: center; } .pro-feat-mb30 { margin-bottom: 30px; } .pro-feat-span { margin: 15px 0px; font-size: 14px; } .pro-feat-list { font-size: 16px; } .pro-feat-list li { margin-bottom: 10px; font-size: 16px; } .pro-feat-mb30 img { padding: 20px 50px 0px; } .pro-feat-mb30 p img { padding: 0px !important; } .pro-feat-mb30 p { padding: 0px 20px; } @media (min-width: 768px) { .pro-feat-align-center { align-items: center; display: flex; } } @media (max-width: 767px) { .pro-feat-mb30 img { padding: 20px; } .pro-feat-mb30 p img { padding: 0px !important; } } </style>
Sizing/specifications
<table> <tbody> <tr> <td class="attrTitle">Brand</td> <td class="attrDat">QuickVue+&nbsp;Strep A</td> </tr> <tr> <td class="attrTitle">Application</td> <td class="attrDat">Respiratory Test Kit</td> </tr> <tr> <td class="attrTitle">CLIA Classification</td> <td class="attrDat">Non-CLIA Waived</td> </tr> <tr> <td class="attrTitle">CLIA Classified</td> <td class="attrDat">CLIA Non-Waived</td> </tr> <tr> <td class="attrTitle">Contents 1</td> <td class="attrDat">(25) Test Cassettes; Extraction Reagant A, Extraction Reagant B, Sterile Throat Swabs, Tubes and Tips, Postive Control, Negative Control, Package Insert, Procedure Card</td> </tr> <tr> <td class="attrTitle">Number of Tests</td> <td class="attrDat">25 Tests</td> </tr> <tr> <td class="attrTitle">Purchase Program Type</td> <td class="attrDat">Standard Purchase</td> </tr> <tr> <td class="attrTitle">Reading Type</td> <td class="attrDat">Visual Read</td> </tr> <tr> <td class="attrTitle">Sample Type</td> <td class="attrDat">Throat Swab Sample</td> </tr> <tr> <td class="attrTitle">Specialty</td> <td class="attrDat">Immunoassay</td> </tr> <tr> <td class="attrTitle">Test Format</td> <td class="attrDat">Cassette Format</td> </tr> <tr> <td class="attrTitle">Test Method</td> <td class="attrDat">Lateral Flow Method</td> </tr> <tr> <td class="attrTitle">Test Name</td> <td class="attrDat">Strep A Test</td> </tr> <tr> <td class="attrTitle">Test Type</td> <td class="attrDat">Infectious Disease Immunoassay</td> </tr> <tr> <td class="attrTitle">Time to Results</td> <td class="attrDat">5 Minute Results</td> </tr> <tr> <td class="attrTitle">Latex Free Indicator</td> <td class="attrDat">Not Made with Natural Rubber Latex</td> </tr> </tbody> </table>
Warranty
<ul><li>The product warranty is applicable as per the terms and conditions provided by the product manufacturer.</li></ul><p><b>Please call us for specific details.</b></p>
Return policy
<ul><li>No returns will be accepted after 30 days from the date of shipment.</li><li>All returns are subject to a restocking fee as per manufacturers terms and conditions.</li><li>All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.</li><li>We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.</li><li><b>The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.</b></li><li>If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.</li><li>Hygiene, bath and toilet items cannot be returned once opened or used.</li><li>Standard manufacturer terms and conditions apply for return policy of this product.</li></ul><p><b>Please call us for specific details.</b>

Looking for more information?

Select Variant
QuickVue+ Strep A Test Kit
$97.97$102.87
Select Packaging :
  • Kit

  • Case

  • Select Group